Supply, installation, commissioning and user training of Biosafety, cold chain, weighing and laboratory water equipment in N'Djamena, Chad
UNOPS
Supply, installation, commissioning and user training of Biosafety, cold chain, weighing and laboratory water equipment in N'Djamena, Chad
Invitation to bid
Reference:
ITB/2026/63677
Beneficiary countries or territories:
Chad
Registration level:
Basic
Published on:
14-Jul-2026
Deadline on:
10-Aug-2026 13:00 0.00
Expired
Description
Tender description: Supply, installation, commissioning and user training of Biosafety, cold chain, weighing and laboratory water equipment in N'Djamena, Chad
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Local communities, MSMEs and supplier diversity
Economic
The tender contains sustainability considerations regarding local MSMEs, local communities or disadvantaged groups.
Examples:
Reserved labour opportunities for local communities, use of local materials, reserved procurements for local companies
Protection of the environment, biodiversity and restoration of natural habitats
Environmental
The tender contains sustainability considerations related to the protection of the environment, biodiversity and restoration of natural habitats.
Examples:
Sustainable/ organic agriculture, fishing or forestry.
| Link | Description | |
|---|---|---|
| https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
New amendment added #1: Amendment No. 1This amendment to the solicitation documents is issued to extend the bid submission deadline until Monday, 10 August 2026, at 14:00 (N'Djamena local time).All other terms and conditions of the solicitation documents shall remain unchanged and in full force and effect.Procurement UnitUNOPS – Chad
Edited on:
03-Aug-2026 12:04
Edited by:
webservice@unops.org
New clarification added: Q35.We kindly request an extension of the tender submission deadline by one week, until 12 August, to allow us sufficient time to finalize the required documentation and submit a complete and compliant proposal.UNOPS Clarification 35.Please refer to "UNOPS Clarification 33".
Edited on:
31-Jul-2026 11:46
Edited by:
webservice@unops.org
New clarification added: Q33.In light of the recently provided installation site address, we require a little additional time to accurately prepare the installation cost estimate.Would it be possible to extend the submission deadline to 10 August?UNOPS Clarification 33.An extension of the bid submission deadline has been considered. An amendment to the solicitation documents will be issued to formally extend the submission deadline until 10 August 2026 at 14:00 (N'Djamena local time).Q34With reference to the requirements set out in Section III – Schedule of Requirements of the tender document, we note that bidders are requested to provide:the contact information for a sample of those partnerships (for verification purposes); andreferences of quality for a sample of local partners.In this regard, we would like to seek your clarification on the following matter:This would be our first collaboration with the proposed local after-sales service partner, and as such, we do not have any prior partnership history with this entity to serve as a reference. Given this circumstance, we would kindly like to inquire whether the following alternative documentation would be considered acceptable for the purpose of compliance:The business license of the local partner, demonstrating its legal capacity to operate in the relevant field;Curriculum vitae of the local partner's personnel who will be assigned to provide the after-sales services; andOur official Letter of Appointment designating this company as our local after-sales service partner for the duration of this project.We would be grateful for your confirmation on whether the above documents would satisfactorily meet the tender requirements, or if any additional information would be required.Best regards.UNOPS Clarification 34.The listed documents shall be considered acceptable, subject to successful verification by the Evaluation team.
Edited on:
31-Jul-2026 11:39
Edited by:
webservice@unops.org
New clarification added: Q32.Regarding the submission part, the Form B is mentioned as mandatory.Could it be possible to make it optional if we are not submitted a bid as a Joint Venture/Consortium/Association.UNOPS Clarification 32.If you are not submitting a bid as part of a joint venture, please complete the relevant section of the form B by indicating "Not Applicable (N/A)".
Edited on:
30-Jul-2026 13:48
Edited by:
webservice@unops.org
New clarification added: Q31.Can you please confirm CPT INCOTERM for delivery of these items as if to N'JAMENA, it should be DAP and if CPT Douala port, Incoterm should be CFR.UNOPS Clarifications 31.According to the tender conditions, the required delivery incoterm is CPT (N'Djamena Airport or Dry Port).
Edited on:
28-Jul-2026 19:27
Edited by:
webservice@unops.org
New clarification added: Q29.I would like to confirm with you that for Lots 2,3 & 4, as per Section IV: Schedule of Requirements, there is no requirement to provide Installation and commissioning and User training services, as these are not mentioned in this document.UNOPS Clarification 29.The equipment included under Lots 2, 3, and 4 is considered plug-and-play and is intended for use in existing laboratories where all required operational facilities and supporting infrastructure are already in place.Accordingly, on-site installation, commissioning, and end-user training services are not required. Bidders shall therefore not include any additional costs for these services in their financial proposals. However, the supplier shall provide all documentation necessary to enable proper installation, operation and maintenance of the equipment, including, when applicable :Installation instructions and site preparation requirements;User manuals;Operation and maintenance manuals;Calibration and configuration procedures, where applicable;Electrical and utility connection requirements;Manufacturer's technical documentation and recommended preventive maintenance instructions.Q30.The equipment shall be delivered factory-tested, complete, ready for connection to the existing utilities, and fully compliant with the technical specifications.Please specify the exact site address for the installation and commission of the laminar flow and fumehood in lot 1.UNOPS Clarification 30.The installation and commissioning site is:Laboratory of the Chadian Institute of Agricultural Research for Development (ITRAD)Farcha, 1st District, N'Djamena, Republic of Chad.The beneficiary laboratory is an existing and fully operational facility with the required basic infrastructure already in place to accommodate the requested equipment.The Chadian Institute of Agricultural Research for Development (ITRAD) is a public scientific and technical institution responsible for research and development in the fields of agriculture, fisheries, forestry, agri-food technologies, and related scientific activities. It operates under the administrative supervision of the Ministry of Agriculture and Irrigation.
Edited on:
27-Jul-2026 15:00
Edited by:
webservice@unops.org
New clarification added: Q20.Is there heat present inside the hood?If so, what is the maximum temperature?"UNOPS Clarification 20.No significant heat sources are anticipated. The conditions are consistent with normal laboratory practices.Q21.Will there be dust present? If yes, please specify the type of dust.UNOPS Clarification 21.No significant dust production is expected. The handling primarily involves liquid reagents and small quantities of laboratory powders.Q22. What tests, Processes are you running in the hood ( Please include what chemicals or other metals are being mixed or if they are being heated ect) This helps us determine what by product fumes we can expect to come off the process or tests)UNOPS Clarification 22.Activities include, but are not limited to :- Sample preparation;- Reagent preparation;- Dilutions;- Dissolution;- Mixing;- Physicochemical analyses;- Analytical laboratory work.Q23.What equipment will be used inside the hood? (e.g., hotplate, Bunsen burner – include dimensions if applicable)"UNOPS Clarification 23.Standard laboratory equipment, which may include, but is not limited to :- Magnetic stirrer;- Laboratory hot plate;- Laboratory glassware;- Small analytical instruments.No equipment generating significant heat or flames is planned.Q24.Do you require any extra utility fittings inside the hood? (e.g., Water, LPG Gas, Compressed Air, Vacuum, Nitrogen)"UNOPS Clarification 24.No specific connections are required. Connections offered by the manufacturer may be accepted but are not a requirement of this tender.Q25.Do you require a small basin/drip cup inside the unit?UNOPS Clarification 25.Yes. In accordance with the technical specifications, an integrated drip tray is required.Q26.Do you need chemical resistant under-counter cabinets?UNOPS Clarification 26.No specific requirements. A support table may be provided in accordance with the tender specifications.Q27Do you need an airflow monitor?UNOPS Clarification 27.No independent flow meter is required. However, the tender specifications require a continuous monitoring system for ventilation and airflow performance with appropriate alarms.Q28. Please describe the environment the hood will be installed in.(e.g., standard lab, clean room class 100, acidic environment)"UNOPS Clarification 28.Standard research and analysis laboratory. The fume hood will be installed in an existing laboratory with standard utilities (220 V / 50 Hz power supply).This is not a cleanroom, a particularly corrosive environment, or an industrial installation.
Edited on:
24-Jul-2026 18:06
Edited by:
webservice@unops.org
New clarification added: Q8.For Item1 Ultrapure water production system (with reservoir) under Lot 4 – Laboratory Water Production and Storage, the manufacturer's water quality test report is prepared in accordance with the Chinese National Standard for analytical laboratory water. This standard is technically aligned with ISO 3696:1987, with certain national adjustments. We confirm that all test results meet or exceed the required technical specifications. We would appreciate your confirmation on whether this compliance approach is acceptable.UNOPS Clarifications 8.The objective of these technical specifications is to procure a laboratory water purification system capable of producing water that meets the required quality performance for the intended laboratory applications, regardless of the national standard referenced by the manufacturer.Accordingly, an analysis report issued in accordance with a Chinese national laboratory water standard is acceptable, provided that the bidder demonstrates that :the referenced standard is technically equivalent to, or more stringent than, ISO 3696:1987 (or another internationally recognized equivalent standard) for the relevant parameters; andthe produced water meets or exceeds the minimum quality requirements specified in the Technical Specifications.The compliance will be assessed based on the manufacturer's supporting technical documentation demonstrating the required performance and equivalence.Recirculating Chemical Fume HoodQ9.Will a ducted or ductless fumehood required. If yes, how long will the duct run internally?UNOPS Clarifications 9.No.The tender documents specify a recirculating chemical fume hood (ductless fume hood) operating without connection to an external extraction system.No extraction duct is planned.Q10.Are we connecting to an existing ducting system or do you require new ducting?UNOPS Clarification 10.No. No connection to an existing extraction network is planned.Q11.Where is the fan exhused to?UNOPS Clarification 11.The filtered air is recirculated within the laboratory according to the operating principle of the proposed fume hood and the performance validated by the manufacturer.Q12.Do you have any height, width or depth restrictions for the space?If yes, Please specifyUNOPS Clarification 12.No particular constraints other than the requirements specified in the tender documents. The existing laboratory allows for the installation of a fume hood with a usable width ≥ 1200 mm. The bidder must adhere to dimensions compatible with their equipment and the functional requirements of the tender specifications.Q13.Do you have a specific height requirment inside the cupboard for tall instruments ?UNOPS Clarification 13.No specific requirements. A standard usable height suitable for common laboratory procedures is expected.Q14.Please describe your application (e.g., pouring, chemical mixing, cleaning parts, etc.).UNOPS Clarification 14.Common laboratory uses:Preparation of solutions ;Dilution ;Weighing of reagents ;Mixing of chemicals ;Sample preparation ;Routine analytical procedures.The fume hood is not intended for industrial processes.Q15.List all chemicals to be used inside the hood, including the concentration of each.UNOPS Clarification 15.The laboratory performs a variety of analyses. No exhaustive list of chemicals can be provided.The Bidder must propose a filtration configuration suitable for general laboratory use, in accordance with tender requirements.Q16.What volume (in mL) of each chemical is expected to evaporate in a 24-hour period?UNOPS Clarification 16.This information is not available. The procedures involve typical laboratory quantities. The bidder is advised to size their filtration system according to the manufacturer's documented performance.Q17.If this information is unknown, please estimate the level of evaporation based on how much of each chemical (in mL) you begin the experiment with and how much of each chemical (in mL) you finish the experiment with."UNOPS Clarification 17.Hot plates may be used occasionally as part of routine analytical procedures. No intensive use generating significant vapor loads is anticipated.Q18.Will any chemicals be heated, boiled, or aerosolized (sprayed)? If yes, please specify which and under what conditions."UNOPS Clarification 18.No.Q19.Will Perchloric Acid be used inside the fume hood?UNOPS Clarification 19.No use of perchloric acid is anticipated.
Edited on:
24-Jul-2026 17:53
Edited by:
webservice@unops.org
New clarification added: Q6.We would appreciate if you could share more information about the chemical products to be used inside the Cabinet of the Ductless Fume Hoods, including the quantities, frequency of use and temperature. This is to confirm which is the best configuration of filters.UNOPS Clarification 6.The fume hoods requested are intended for general laboratory use for handling small quantities of reagents. At this stage, it is not possible to provide an exhaustive list of chemicals, quantities, frequencies of use, or operating temperatures, as these parameters may vary depending on the activities of the beneficiary laboratories.Therefore, bidders are invited to propose a fume hood equipped with a filtration configuration suitable for versatile laboratory use, in accordance with the published technical specifications and the manufacturer's recommendations.Q7.We would like to clarify if Multiple technicallly compliant alternative solutions can be proposed for each line item.UNOPS Clarification 7.In accordance with the tender particulars, alternatice offers are not acceptable. Bidders must present one bid that fully meet the tender minimun requirements.
Edited on:
21-Jul-2026 22:59
Edited by:
webservice@unops.org
New clarification added: Q3.With reference to the Item2 Purified Water Storage Tank under Lot 4 – Laboratory Water Production and Storage, the technical specification requires that the tank "Complies with ISO 3696 or ASTM D1193." However, we would like to respectfully point out that both ISO 3696 and ASTM D1193 are standards that define the quality specifications for purified water, rather than standards applicable to the storage tank itself. As such, these standards do not appear to be relevant or applicable to the storage container. We kindly seek your confirmation on whether this is a typo, and if the intended standards should instead be IEC/EN 61010 and IEC/EN 61326.UNOPS Clarification 3.Purified Water Storage TankIt is correct that ISO 3696 and ASTM D1193 define requirements for laboratory water quality, not for the design characteristics of a storage tank.The intention of the published specifications was not to require certification of the tank according to these standards, but to ensure that it is suitable for storing water meeting the requirements for Type I and/or II laboratory water produced by the purification system without compromising the quality of the purified water..Therefore, we confirms that :- The references to ISO 3696 and ASTM D1193 should be understood as requirements for the quality of the water to be stored, and not as certification applicable to the tank itself;- The proposed tank must be manufactured using materials suitable for storing purified / ultrapure water, exhibiting low contaminant release and compatible with the laboratory applications described in the tender specifications.- When electrical or electronic components are integrated into the tank (such as : electronic level indicators, sensors, or control devices), their compliance with applicable safety and electromagnetic compatibility standards, such as IEC/EN 61010 and IEC/EN 61326, is acceptable when relevant to the components in question.Q4.For laboratory Freezer (-20°C) – Forced Convection Requirement (Lot 2, Item 3),the specification requires "forced convection ensuring thermal uniformity" for the -20°C laboratory freezer. However, our proposed unit uses direct cooling technology (static convection) and also achieves excellent thermal uniformity. Please kindly confirm if this would be acceptable.UNOPS Clarification 4.The objective of this specification is to obtain a laboratory freezer capable of maintaining a homogeneous and stable temperature throughout its usable volume to ensure proper sample preservation. The reference to ''forced convection'' corresponds to a commonly used technical solution for achieving this performance, but is not an exclusive requirement.Consequently, we confirms that :A freezer using direct cooling technology (static convection) is acceptable ; this technology must, however, demonstrate that it meets the minimum performance requirements specified in the tender documents, including :- the required temperature range ;- thermal stability ≤ ±1°C ;- thermal uniformity ≤ ±2°C ;- as well as all other published functional requirements.Bidders must provide the manufacturer's technical documentation demonstrating the proposed equipment's compliance with these performance requirements. The method of cold circulation is therefore not a disqualifying criterion provided that the minimum required performance requirements are fully met.Q5.For Item3 Digital Precision Benchtop Electronic Scale, Capacity 5 kg, under Lot 3 Laboratory weighing and metrology equipment, the technical specification requires an electromagnetic load cell or equivalent high-stability technology. our proposed equipment utilizes a strain gauge load cell that we believe offers equivalent high stability. Could you please confirm whether this is acceptable?UNOPS Clarification 5.Electronic Precision Bench Balance (5 kg) The objective of the published technical specifications is to procure a laboratory precision balance capable of providing stable, accurate and repeatable weighing performance for routine laboratory applications. The reference to an electromagnetic weighing cell is intended to describe a proven weighing technology capable of achieving the required metrological performance. As explicitly stated in the specification, the wording "or equivalent high-stability technology" allows the use of alternative weighing technologies, provided that they demonstrably achieve equivalent functional and performance characteristics.Therefore :A balance using a strain gauge load cell may be considered acceptable provided that the proposed equipment fully complies with all the minimum technical and performance requirements specified in the bidding Document.In particular, bidders shall clearly demonstrate, through the manufacturer's official technical documentation, that the proposed balance achieves at least :- Maximum capacity ≥ 5,000g ;- Readability : 0.01g ;- Repeatability : ≤ ±0.01g ;- Linearity : ≤ ±0.02g ;- Stabilization time : ≤ 3 seconds ;- Long-term measurement stability suitable for laboratory use under normal operating conditions.The bidders shall also demonstrate compliance with all other technical requirements, including functional features, communication interfaces, applicable safety standards, and conformity requirements.The proposed equipment will be evaluated based on its demonstrated compliance with the complete technical specifications and supporting manufacturer documentation.
Edited on:
21-Jul-2026 13:08
Edited by:
webservice@unops.org
New clarification added: Q1. Regarding Item 1 of Lot 2, the usable volume of the combined biomedical refrigerator-freezer: is it acceptable if the usable volume of our equipment is either larger or smaller than the specified range? For example, the usable volume of our equipment is 225L, while your required range is 250–300L. Would this be acceptable?UNOPS CLARIFICATION 1. The technical specification defines the minimum storage capacity required to meet the operational needs of the beneficiary laboratories.Accordingly :- For the refrigerator compartment, the required usable volume shall be between 250 and 300 litres;- For the freezer compartment, the required usable volume shall be between 180 and 200 litres.Bidders are therefore requested to comply with these specified usable volume ranges.Q2. We kindly request clarification regarding the Lot 3 the required capacity and least count (readability) for the three weighing scales specified in the tender.The standard models available from the manufacturer are as follows:Scale Capacity Least Count (Readability)1 220g 0.0001 g (0.1 mg)2 3200g 0.01 g (10 mg)3 6200g 0.01 g (10 mg)Kindly confirm whether the above standard capacities and readability values are acceptable. If different specifications are required, we would appreciate it if you could confirm the exact capacity and least count (readability) required for each of the three weighing scales.UNOPS CLARIFICATION 2. The objective of the technical specifications is to procure 03 laboratory balances intended for different weighing applications, namely analytical weighing, routine laboratory weighing and general precision weighing.Accordingly, the required minimum performance remains as specified in the Bidding Documents. We confirm the following minimum requirements :1. Analytical balance :- Minimum capacity : ≥ 220g,- Minimum readability : 0.001g.2. Precision laboratory balance :- Minimum capacity : ≥ 3000g,- Minimum readability : 0.001g.3. Precision bench balance :- Minimum capacity : ≥ 5000g,- Minimum readability : 0.01g.Bidders shall therefore propose equipment that comply with the minimum technical requirements stated above or offering superior performance where applicable. All other technical specifications and compliance requirements of the Bidding Documents remain unchanged.
Edited on:
20-Jul-2026 19:16
Edited by:
webservice@unops.org