CANCELLED Supply, Delivery and Installation of Diesel Generator Set for Kassala Health Citadel Project at Kassala State, Sudan.
UNOPS
CANCELLED Supply, Delivery and Installation of Diesel Generator Set for Kassala Health Citadel Project at Kassala State, Sudan.
Request for quotation
Reference:
RFQ/2026/63651
Beneficiary countries or territories:
Sudan
Registration level:
Basic
Published on:
10-Jul-2026
Deadline on:
16-Jul-2026 10:00 0.00
Description
TENDER DESCRIPTION:
The United Nations Office for Project Services (hereinafter referred to as UNOPS) is pleased to invite competent Bidders/Contractors to submit their respective competitive bids for the Supply, Delivery and Installation of Diesel Generator Set for Kassala Health Citadel Project at Kassala State, Sudan. in accordance with the UNOPS General Conditions of Contract and the Technical Specification/“Schedule of Requirements” herein uploaded under “Document” TAB
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
The United Nations Office for Project Services (hereinafter referred to as UNOPS) is pleased to invite competent Bidders/Contractors to submit their respective competitive bids for the Supply, Delivery and Installation of Diesel Generator Set for Kassala Health Citadel Project at Kassala State, Sudan. in accordance with the UNOPS General Conditions of Contract and the Technical Specification/“Schedule of Requirements” herein uploaded under “Document” TAB
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
| Link | Description | |
|---|---|---|
| https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
26111601
-
Diesel generators
Tender cancelled on 2026-08-07 11:23 UTC. The solicitation has been cancelled following an internal review of the procurement requirements. UNOPS intends to review the requirements and may relaunch the solicitation accordingly. For any inquiries, please contact Engi ABUBUKER SAEED ALHASSAN. Email: EngiA@unops.org, Phone: Sudan 110010106
Edited on:
07-Aug-2026 13:23
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Thank you for your interest in this tender. UNOPS responses to the clarifications as follows: Question 1: In part one General/ section 1&2 you mentioned the following: 1.415V, 50Hz, TP+N power factor 0.8(lagging)Prime 400 kVA Standby 440 kVA2. The Diesel Generator engine output power, alternator, controller, and all accessories to besized for maximum outdoor ambient temperature 50Co and proving technical data sheets to besubmitted with technical documentswhile in section 2.2 A/ Part 2you mentionedProvide stand-by packaged type electrical power diesel engine-driven, turbochargedgenerator assembly units, site rated as shown at a governed speed of 1500 RPM at 80percent power factor for continuous operation, 415/240 V, 50 Hz at 50°C deratedaccording to site elevation for altitude ≥1000m and humidity≥90.Does it mean your operating load is 400KVA in these conditions 50C and 1000 m altitudeOr the engine will operate in these conditions?Normally it should be stated clearly if this is the load or the generator designed load...If this is the load then you would not say the standby is 440KVA..you will say this my load and the engine would not be exiplicitly described....We can upgrade the engine or the alternator to avoid the derating that will accompany the humidity and the altitude while operating in 50C...Answer: The two points convey the same requirement. However, the first point has been included to emphasize that the generator unit must be rated for continuous operation at an ambient temperature of 50°C, as many suppliers offer units designed for the standard ambient temperature of 25°C. Such units will not meet the project requirements and will therefore be considered non-compliant and rejected.Question 2: 2.Now the No of units reduced to only one instead of two.Answer: Yes, only one (1) generator set is required.Question 3: External fuel tank is added with extra costAnswer: As specified in the technical requirements, the generator shall be supplied with both an integral fuel tank providing 24 hours of operation and a 500-liter external fuel tank.Question 4: As per your requirement of 400 kva prime and 440 kva standby at 50 degrees c and 1000m Altitude and 400kva prime will have deration upto 2% ( i can attached deration chart) So please advise if 2% deration is accepted which will give 392kva prime and 441kva standby or we have to go with next size which is 450kva Prime and 500 kva standby and this will engine does not have any deration at 50 degrees C ( can share deration chart on request). Answer: No derating will be accepted. The generator set shall fully comply with the specified rated output of 400 kVA Prime and 440 kVA Standby at an ambient temperature of 50°C and an altitude of 1,000 m, without any reduction in capacity.Question 5: Also regardng Attenuation 65-70 dBA at 3meter is right or it is at 7 meter. If we add more insulation then we have design customised genset to increase canopy size so as to fit air supply design at 110% load without heating genset . Please adviseAnswer: As per the tender specification, the required noise level is 70 dB(A) ±3 at 1 meter from the generator set with the soundproof canopy.
Edited on:
14-Jul-2026 11:25
Edited by:
webservice@unops.org