Tender description: This RFQ refers to the Supply of Laboratory Equipment (Part CXX ) for SES of the Republic of Uzbekistan. The requirement consist of 1 item:
Item no# 1: Videoendoscopic system (gastroscope + colonoscope): Qty 1 set
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
Item no# 1: Videoendoscopic system (gastroscope + colonoscope): Qty 1 set
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Sustainable resource use
Environmental
The tender contains sustainability considerations promoting the sustainable use of resources.
Examples:
Energy-saving measures, recycling, take-back programmes and responsible end-of-life management
| Link | Description | |
|---|---|---|
| https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
New amendment added #1: The RFQ is hereby amended to reflect the changes for technical specifications for the Item.The document title "RFQ_Section_III_Returnable_Bidding_Forms_Form C_Technical Bid Form" is hereby replaced with the updated document titled "RFQ_Section_III_Returnable_Bidding_Forms_Form C_Technical Bid Form_Rev01".
Edited on:
15-May-2026 20:13
Edited by:
webservice@unops.org
New clarification added: Q12. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section J (At least 24 months from the date of commissioning; defects must be fixed within 10 days.), could you please kindly extend the defect resolution period to 30 days, as the current 10-day limit is not practically feasible for complex videoendoscopic systems. Given the need for specialized components and potential international logistics, a 30-day timeframe would ensure repairs are completed in accordance with manufacturer safety and calibration standards without compromising patient care.A12. The request is partially accepted.The warranty support requirement will be revised as follows:“Supplier must respond to service requests within 48 hours. Defects requiring standard repair shall be resolved within 10 working days whenever spare parts are locally available. In cases requiring international spare-part procurement or factory-level repair, the resolution period may be extended up to 30 calendar days.”
Edited on:
13-May-2026 05:01
Edited by:
webservice@unops.org
New clarification added: Q11. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 96 (Multi-band ligators: For esophageal varices, at least 7 rings (100 pcs)), could you please kindly adjust the requirement for multi-band ligators to “at least 6 rings,” as the current 7-ring minimum is unnecessarily restrictive and excludes several industry-standard, clinically proven ligation systems used globally. Since standard therapeutic protocols typically utilize 4–6 bands per session, a 6-ring threshold would maintain full clinical efficacy while supporting a more competitive and cost-effective bidding process.A11. As per the end user’s request, this technical requirement remains unchanged.
Edited on:
13-May-2026 05:00
Edited by:
webservice@unops.org
New clarification added: Q10. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 49 (Air pressure adjustment (Max, High, Medium, Low)), could you please kindly amend the requirement for “Air pressure adjustment” to “At least 3 levels of pressure adjustment”? The current specification of four defined levels (Max, High, Medium, Low) reflects a proprietary labeling convention rather than a clinical performance requirement, and this revision would allow inclusion of all high-performance systems that provide the necessary pressure control for patient safety and procedural efficiency.A10. The request is accepted.The specification will be revised as follows:“Air pressure adjustment: at least 3 selectable levels.”
Edited on:
13-May-2026 04:59
Edited by:
webservice@unops.org
New clarification added: Q9. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 40 (RDI or DHI (Deep Vessel Emphasis and Hemorrhage Source Imaging) function), could you please kindly revise the text to: “Deep Vessel or Hemorrhage Source Emphasis function (RDI, DHI, ACI, or equivalent)”? The current specification references proprietary technologies exclusive to certain manufacturers, whereas a performance-based description would enable fair evaluation of all advanced systems that provide the essential clinical capability of identifying bleeding sources and deep vascular patterns.A9. The request is accepted.The specification will be revised as follows:"RDI or DHI (Deep Vessel Emphasis and Hemorrhage Source Imaging) or equivalent function”
Edited on:
13-May-2026 04:59
Edited by:
webservice@unops.org
New clarification added: Q8. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 39 (NBI (Narrow Band Imaging) / SFI (Spectral Focused Imaging) function), could you please kindly amend the technical requirement in Line 39 to: “Advanced Optical or Digital Image Enhancement mode (e.g., NBI, BLI, LCI, i-scan, or equivalent spectral imaging)”? The current wording references proprietary trade names that are exclusive to specific manufacturers, and the inclusion of “or equivalent” is important to support fair competition and ensure access to the most clinically effective image-enhancement technologies available on the market.A8. The request is partially accepted.The specification will be revised as follows:“NBI (Narrow Band Imaging) / SFI (Spectral Focused Imaging) function or equivalent”
Edited on:
13-May-2026 04:58
Edited by:
webservice@unops.org
New clarification added: Q7. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 35 (Color correction (Red, Green, Blue, Amber): At least 5 levels of adjustment for each), could you please kindly remove the requirement for “Amber” color adjustment and revise the parameter to: “Color correction (Red, Green, Blue): At least 5 levels of adjustment for each”? The inclusion of Amber is a non-standard industry requirement that may unnecessarily restrict competition to proprietary technologies, whereas standard RGB adjustment—particularly with higher sensitivity levels—provides sufficient control for accurate mucosal visualization and clinical performance.A7. The request is accepted.The specification will be revised as follows:“Color correction (Red, Green, Blue): at least 5 levels of adjustment for each.”
Edited on:
13-May-2026 04:57
Edited by:
webservice@unops.org
New clarification added: Q6. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 33 ( "Light source service life: Not less than 60,000 hours (If the service life is lower than that specified, then the corresponding number of lamps can be added)), could you please kindly adjust the minimum light source service life requirement to 10,000 hours, as the current 60,000-hour specification is excessive and not aligned with the technical standards of leading medical LED systems? Requiring a 60,000-hour lifespan—equivalent to more than 20 years of typical use—may unnecessarily increase costs by compelling bidders to include additional spare components, while limiting access to the most advanced diagnostic technologies currently available.A6. The request is partially accepted.The technical requirement will be revised as follows:“Light source service life: not less than 30,000 hours (If the service life is lower than that specified, then the corresponding number of lamps can be added).”
Edited on:
13-May-2026 04:57
Edited by:
webservice@unops.org
New clarification added: Q5. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 32 (LED light source power: Not less than 50 W), could you please kindly revise the requirement for LED light source power from a fixed 50 W input to a performance-based standard, such as “equivalent to a 300 W Xenon light source” or a minimum luminous flux value? Wattage reflects electrical consumption rather than actual illumination performance, and the current specification may unnecessarily exclude high-efficiency LED systems that provide superior clinical brightness with lower power consumption and reduced heat generation.A5. The request is accepted.The technical requirement will be revised as follows:“Light source: LED with power not less then 50W or LED with illumination performance equivalent to or higher than a 300W Xenon light source.”
Edited on:
13-May-2026 04:56
Edited by:
webservice@unops.org
New clarification added: Q4. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 22 (Working length: Not less than 1700 mm), could you please kindly adjust the minimum working length to 1680 mm, as the current 1700 mm requirement is unnecessarily restrictive and excludes industry-standard high-definition colonoscopes from major manufacturers such as Olympus and Fujifilm, which provide equivalent clinical reach while supporting broader technological capabilities for patient care.A4. The request is accepted.The technical requirement will be revised as follows:“Working length: not less than 1680 mm.”
Edited on:
13-May-2026 04:55
Edited by:
webservice@unops.org
New clarification added: Q3. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 20 (Insertion tube diameter: Not more than 12.0 mm), could you please kindly adjust the maximum insertion tube diameter to 13.2 mm, as the current 12.0 mm limit is technically restrictive and incompatible with standard high-performance adult therapeutic colonoscopes, which typically feature a 12.8 mm shaft to provide the durability, suction performance, and anti-looping stiffness required for routine adult gastroenterology procedures.A3. As per the end user’s request, and in order to ensure improved patient comfort, reduced procedural invasiveness, and compatibility with minimally traumatic lower GI endoscopy practices, this technical requirement remains unchanged.
Edited on:
13-May-2026 04:54
Edited by:
webservice@unops.org
New clarification added: Q2. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 19 (Distal end diameter: Not more than 11.8 mm), could you please kindly adjust the maximum distal end diameter to 13.2 mm, as the current 11.8 mm limit is overly restrictive and excludes standard high-performance adult therapeutic colonoscopes, which typically measure 12.8 mm. This revision would help ensure broader competitive participation without compromising the therapeutic capabilities required for comprehensive adult gastroenterological care.A2. The request is partially accepted. The specified distal end diameter requirement will be changed to "not more than 12 mm" in order to ensure improved patient comfort, reduced procedural invasiveness, and compatibility with minimally traumatic lower GI endoscopy practices.
Edited on:
13-May-2026 04:53
Edited by:
webservice@unops.org
New clarification added: Q1. As per RFQ_Section_III_Returnable_Bidding_Forms_Form C - Technical Bid Form, Item No 1 Videoendoscopic system (gastroscope + colonoscope), Section B - Technical Specifications, Line 6 ( Depth of field: in the range of at least 0-100 mm), could you please kindly revise the lower limit to 2 mm, as a 0 mm focal point is clinically impractical for clear visualization and exceeds standard optical limitations for endoscopic lenses? This adjustment would support a broader range of high-quality competitive bids without compromising clinical utility.A1. The request is accepted.The technical requirement will be revised as follows:“Depth of field: in the range of 2–100 mm or wider”.