Long-Term Agreement for the Supply of High-Complexity Medical Devices for UNOPS in the Caribbean and the Queen Elizabeth Hospital in Barbados
UNOPS
Long-Term Agreement for the Supply of High-Complexity Medical Devices for UNOPS in the Caribbean and the Queen Elizabeth Hospital in Barbados
Invitation to bid
Reference:
ITB/2026/61229
Beneficiary countries or territories:
Multiple destinations (see the Countries or territories tab)
Registration level:
Basic
Published on:
26-Mar-2026
Deadline on:
13-May-2026 17:30 0.00
Expired
Description
Tender description: ITB/2026/61229 - Long Term Agreement for the Supply of Medical Devices - High Complexity for UNOPS in the Caribbean and for the Queen Elizabeth Hospital in Barbados.
The procurement is divided into 8 lots as follows:
- High-Complexity Medical Devices (HC):
UNOPS, on behalf of the Ministry of Health and Wellness (MHW) of Barbados, is implementing the Queen Elizabeth Hospital strengthening and improvement support project. As part of the implementation of the project, the objective of this Invitation to Bid (ITB) is to establish non-exclusive Long Term Agreements (LTAs) with multiple qualified vendors for the procurement of Medical Devices - High Complexity for countries in the Caribbean and for the Queen Elizabeth Hospital in Barbados.
The LTAs also will allow UNOPS to respond to future needs that might arise in these countries by issuing Call of Orders against these LTAs.
UNOPS may, after consulting with the awarded suppliers, use these LTAs to supply other countries not located in the Caribbean.
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
The procurement is divided into 8 lots as follows:
- High-Complexity Medical Devices (HC):
- Lot 1: HC - Anaesthesia machine
- Lot 2: HC - MRI Anaesthetic machine
- Lot 3: HC - Autoclave
- Lot 4: HC - Medium Autoclave
- Lot 5: HC - Bariatric surgical table
- Lot 6: HC - Electrosurgical unit
- Lot 7: HC - Surgery lamps (2-dome and 3-dome)
- Lot 8: HC - Ultrasonic cleaner for instruments
UNOPS, on behalf of the Ministry of Health and Wellness (MHW) of Barbados, is implementing the Queen Elizabeth Hospital strengthening and improvement support project. As part of the implementation of the project, the objective of this Invitation to Bid (ITB) is to establish non-exclusive Long Term Agreements (LTAs) with multiple qualified vendors for the procurement of Medical Devices - High Complexity for countries in the Caribbean and for the Queen Elizabeth Hospital in Barbados.
The LTAs also will allow UNOPS to respond to future needs that might arise in these countries by issuing Call of Orders against these LTAs.
UNOPS may, after consulting with the awarded suppliers, use these LTAs to supply other countries not located in the Caribbean.
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Gender issues
Social
The tender contains sustainability considerations addressing gender equality and women's empowerment.
Examples:
Gender mainstreaming, targeted employment of women, promotion of women-owned businesses.
Prevention of pollution
Environmental
The tender contains sustainability considerations for the prevention of polluting emissions to air, solid waste to land and discharges to water.
Examples:
EMS, waste management and wastewater management.
| Link | Description | |
|---|---|---|
| https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
New amendment added #2: Amendment no. 2Interested bidders in the ITB/2026/61229 Long-Term Agreement for the Supply of High-Complexity Medical Devices process should take into account the modifications included in the document "Amendment No. 2 ITB_2026_61229.pdf", available in the Documents Section Taking this amendment into account, the rest of the documents in the tender remain unchanged.
Edited on:
07-May-2026 19:59
Edited by:
webservice@unops.org
New clarification added: Clarification Note No. 3 (Part 3)Question No. 42: We have reached out directly to the Manufacturers for the FX8 however they are stating this unit is currently unavailable, and are inquiring if you will consider their FT10 unit.Answer: Please refer to answer to question no. 33Question No. 43: Kindly confirm if we are responsible for the removal of any existing machines in the location where the new machines that are being procured in lot 3, 4, 7.1, 7.2 & 8 should be installed. If so please provide further details.Answer: Please be advised that the removal and uninstallation of existing equipment will be managed by Queen Elizabeth Hospital (QEH).Question No. 44: In relation to the ultrasonic cleaner in lot 8 kindly advise the distance between the expected placement of the unit and the hospital's water supply network. Kindly also provide to us the diameter of the instruments that the sealing adapters should be designed to accomodate.Answer: a) The water supply will be according to the pre installation requirements of the equipment and for the first Call Off Order, the Queen Elizabeth Hospital will perform the pre-installation activities.b) Please refer to Amendment no. 1 to Section II Schedule of requirements:“Before the Call Off Order is issued, the hospital or final user will select two of the available options from the supplier. The supplier must include a catalog detailing the different equipment option sets.” UNOPS
Edited on:
02-May-2026 01:21
Edited by:
webservice@unops.org
New clarification added: Clarification Note No. 3 (Part 2)Question No. 31: Lot No 2-F1-Three vaporizers: Sevolflurane ,Isoflurane, Desuflane. Desuflane is no longer used. Can you advise on this.Answer: Please refer to Amendment No. 1, Section II Schedule of Requirements Amendment 01. Vaporizers requirement for Lot no. 2: Mandatory one (1) Sevoflurane and one (1) Isoflurane. Desirable but not mandatory one (1) Desflurane. With a visual indicator of the filling level of the anaesthetic agent, and adapter for filling the vaporizer if required.Question No. 32: Lot No 7- who is responsible for the pre-installation -removal of old lights ,electrical and civil works (the hospital or the supplier).Can we get a site visit for this lot since this would require civil and electrical works ?Answer: Please be advised that the Queen Elizabeth Hospital (QEH) will manage all pre-installation works, including the decommissioning and removal of existing lamps and electrical standardizing. The supplier’s responsibility will be limited to final installation and commissioning.Question No. 33: We have reached out directly to the Manufacturers for the FX8 however they are stating this unit is currently unavailable, and are inquiring if you will consider their FT10 unit.Answer: Please refer to Amendment No. 1 to Section II Schedule of requirements, a note has been included for Lot no. 6: “In the event that the requested model has reached its End of Sale (EOS) or End Of Life (EoL) status, we will accept the current equivalent model from the same manufacturer. This is subject to the condition that the new model fulfills the same functional and technical requirements. The proposal must include a formal 'End of Sale' notice or certificate issued by the manufacturer regarding the original model”Question No. 34: Kindly confirm regarding the installation of the Surgical Lamps if you are replacing older units at the location or are we installing the surgical lights in the area for the first time. Kindly do confirm the height of area from floor to ceiling for the installation of surgery lamps in Lot 7 both 7.1 & 7.2. Answer: Please refer to Amendment No. 1, Section II Schedule of Requirements Amendment 01, please revise the following installations considerations for Lot no. 7:The supplier must account for specific height measurements during installation, which vary by Call Off OrderFirst Call Off Order (Barbados):- Floor to ceiling height: 2.74 m (± 0.01 m)- Floor to slab height: 3.49 m (± 0.01 m)- Confirmation: The exact heights will be provided prior to the contract signing.Subsequent Call Off Orders:The heights will be communicated when the request is made. Question No. 35: Regarding Lot No. 2: HC-MRI Anaesthetic Machine, please note that the accessory desflurane vaporizer requires a dedicated electrically heated and pressure-controlled unit. Its core electrical components, including heating elements, sensors, control boards and solenoid valves, cannot be fully magnetically shielded against MRI magnetic fields. Magnetic interference may lead to concentration drift, functional failure and potential safety hazards, and such electromagnetic conflicts are physically unavoidable.Therefore, the desflurane vaporizer is not suitable for use in an MRI environment. We strongly advise not to include the desflurane vaporizer as an accessory for the HC-MRI Anaesthetic Machine. Answer: Please refer to answer to question no. 31Question No. 36: We are writing to seek clarification on the local agent requirement for the tender with reference ITB/2026/61229.a) Whether the local agent must be legally registered and based in Barbados;b) If agents from other countries in the Caribbean region (e.g., Trinidad and Tobago, Jamaica, Guyana) would be acceptable, provided they meet the necessary legal and operational criteria to support project delivery in Barbados. Answer: Please refer to Amendment No. 1, Section II Schedule of Requirements, specifically Subsections F.1 and F.2, which states for both products Type 2 and 3:"Local technical support: If the Supplier is not a Company established in Barbados or the final destination country, the Supplier shall supply post sales services through an experienced Company established in Barbados or the final destination country. The local technical support Company shall count with demonstrated experience of technical support for the same or similar equipment of the offered item. The name of the local technical support company, along with the name and contact information of the responsible person, must be declared by the bidder upon submitting the offer. Documentation demonstrating the experience of the local technical support company, as well as a letter of acceptance from said company agreeing to be jointly and severally liable with the Supplier and manufacturer for the post-sales services and warranty described below, must be delivered to UNOPS before the contract is signed."Question No. 37: We note that the first order requires DAP delivery terms. We would like to confirm whether CIF terms are acceptable.We have contacted a number of freight forwarders, and none are able to provide DAP service to the designated destination.We also note that the delivery location (Queen Elizabeth Hospital) is very close to Bridgetown Sea Port, approximately a 10-minute drive by car.Given the short distance, could you please agree to amend the delivery terms to CIF Bridgetown Sea Port for the first order? Answer: Please be advised that the request to change the delivery terms from DAP to CIF is not accepted. Please refer to answer to question no. 8Question No. 38: We are requesting an extension for this tender.Answer: Please refer to Amendment No. 1, the deadline for submitting offers has been updated to May 11. 2026 before 13:30 Barbados time (17:30 UTC)Question No. 39: We have been informed that the timeline for delivery for two items exceeds the 90 day requirement. The anaesthesia machine has a 23 week production time and a 2 weeks for logistics and the surgical lights have a 3 week production time and 2 weeks for logistics. Kindly advise if this will be acceptable.Answer: Please refer to Amendment No. 1, Section II Schedule of Requirements Amendment 01. The Delivery time has been extended to 150 days after the Call Off Order is placed.Question No. 40: We are kindly requesting a 5 day extension for this tender. Answer: Please refer to answer to question no. 38Question No. 41: In relation to the autoclaves in section 3.1 and 4.1, kindly advise if these units are replacing older existing units at the same location where these new ones would be installed or advise if it is a new site all together.Answer: Please be advised that the new units will replace existing ones
Edited on:
02-May-2026 01:18
Edited by:
webservice@unops.org
New clarification added: Clarification Note No. 3Dear Sir/Madam,In reference to the Invitation to bid ITB/2026/61229 for provision of Medical Devices - High Complexity for UNOPS in the Caribbean and for the Queen Elizabeth Hospital. In this regard, we are issuing this Clarification Note No. 3, which should be considered when preparing your bid.Question No. 15: As per Form D Technical Quotation Form requirement: Plug Type G is requiredHowever , Type A/B is widely used in Barbados, please confirm the correct plug type requirement. Answer: Please refer to Amendment No. 1 to Section II Schedule of requirements, which modifies the requirement as follows: "First Call off order must be Plug Type G. Subsequent call off orders will be determined by the Requester at no additional cost"Question No. 16: As per the Minimum technical requirements, it is mentioned For the first Call Off Order (DAP Barbados): The training will take place at the manufacturer's facility.Could you please clarify whether the training can be taken place in manufacturer's authorized distributor's place?Would it be acceptable for the manufacturer to send trainers to Barbados instead, or to conduct the training at a closer facility, such as the manufacturer's training center in Mexico or Panama? Answer: Please refer to Amendment No. 1 to Section II Schedule of requirements, which modifies the training requirements for Lots 1, 2, 3, 7, and 8 as follows:"Technical and maintenance training may be conducted at an official manufacturer's training center or at the manufacturer's facility. The venue must be a certified facility owned or officially sanctioned by the manufacturer, ensuring that all technical standards are met and specialized tooling is available. Furthermore, instructors must hold current manufacturer certification as technical service trainers to ensure comprehensive knowledge transfer for both preventive and corrective maintenance. To ensure effective communication and the accurate transfer of complex technical data, all trainers must be fluent and competent in English. This includes the ability to explain technical schematics, conduct hands-on demonstrations, and respond to detailed technical inquiries from QEH personnel in English without the need for an interpreter. The bid must include all associated expenses, such as round-trip transportation from Barbados, accommodations and meals for one (1) technician from the Queen Elizabeth Hospital." Question No. 17: As per training requirement ,for the first call off order , the technician personnel training is expected to take place at the manufacturers'place. We would like to confirm if such training can be commissioned locally .Answer: Please refer to answer to question no. 16Question No. 18: Do you accept FCA or CFR incoterm?Answer: Please refer to answer to question no. 8Question No. 19: Do you accept external registered companies outside your country to participate and to be equally evaluated with local registered companies?Answer: Please refer to answer to question no. 9Question No. 20: Will importing and customs clearance be done under UNOPS name in your country?Answer: Please refer to answer to question no. 10Question No. 21: We are distributor of many manufacturers but those vendors have no local representatives in your country. So would you accept shipping you the items and full process of customs clearance to be done under your name?Answer: Please refer to answer to question no. 11Question No. 22: Customs clearance for importing will be done from A-Z by the you and there will be 100% VAT except and customs fees except 100%. So nothing will be paid by the supplier?Answer: Please refer to answer to question no. 11Question No. 23: Would you please accept offered items made in India or China or any other country?Answer: Please refer to answer to question no. 5Question No. 24: Would you accept offer if only one certificate available ISO or CE or FDA. Mostly FDA not available?Answer: Please refer to Amendment No. 1 in which the requirement of Marketing authorization or recognition from regulatory agencies, has been included in Section II: Schedule of Requirements, Subsection E. Certification and technical documentationQuestion No. 25: Is there any installation or maintenance required?Answer: Please refer to Amendment No. 1 to Section II Schedule of Requirements, specifically Subsections F.1 and F.2. We recommend reviewing these carefully, as the tender includes mandatory requirements for installation, commissioning, and long-term maintenance as part of the after-sales service package.Question No. 26: Is any mandatory periodic maintenance required for this project?Answer: Please refer to answer to question no. 25Question No. 27: Do you accept partial quoting, or must two items be quoted?Answer: Please be advised as per eSourcing section "Particulars", Bidders shall be allowed to quote prices for one or more lots identified in this tender. However, bidders must offer FCA and DAP unit prices for the 100% of the items specified for each lot. Evaluation and award will be done per lot.Question No. 28: Will you accept signing the contract and PO in our company name? Plus, will payment be made to our bank account in another country?Answer: UNOPS will enter into contracts with legally established companies and in accordance with the terms and clauses specified in Section_IV_Contract Forms.pdf, attached to this tender. Following the award, contracts will be formally executed by both parties. UNOPS will ask to awarded bidders to fill out a Supplier registration form, the supplier will have to enter their bank account information in order to receive payment from UNOPS via bank transfering, please be advised that the name of the account has to match the supplier's nameQuestion No. 29: Kindly advise if we have to submit the tender documents on both Euna and UNOPS platforms for this tender.Answer: Please be advised that the submissions to this tender are only allowed on the eSourcing UNOPS platform. Please revise the following link to access guidance of the platform usage and how to submit an offer: https://esourcing.unops.org/#/Help/Guides Question No. 30: Item 9 in each requirement-For the first Call Off Order (DAP Barbados) The training will take place at the manufacturer`s facility -If we are unable to provide can we still bid?We can only provide -For next Call Off Orders . Answer: Please refer to answer to question no. 16. These training requirements are mandatory for compliance with the tender specifications.
Edited on:
02-May-2026 01:13
Edited by:
webservice@unops.org
New amendment added #1: Amendment no. 1Interested bidders in the ITB/2026/61229 Long-Term Agreement for the Supply of High-Complexity Medical Devices process should take into account the modifications included in the document "Amendment No. 1 ITB_2026_61229.pdf", available in the Documents Section Taking this amendment into account, the rest of the documents in the tender remain unchanged.
Edited on:
01-May-2026 23:40
Edited by:
webservice@unops.org
New clarification added: MINUTES PRE-BID MEETING1. IntroductionA pre-bid meeting was held on Wednesday, April 15, 2026, at 9:00 a.m. (Barbados local time) via Google Meet.As stated in the eSourcing platform, specifically in the particulars section in “Additional Information”, the clarification meeting shall be conducted on this day and date and participation is not mandatory, but is strongly recommended to avoid the risk of non-compliant bids.2. Q&A and ClarificationsIt was emphasized that UNOPS would not provide official responses to bidders' questions regarding the Invitation to Bid during the clarification meeting. All questions must be submitted in writing through the UNOPS eSourcing platform.Bidders were cautioned not to rely on any statements, assertions, or information provided during the pre-bid meeting unless confirmed in writing by UNOPS.3. Presentation OverviewThe meeting included a presentation covering general administrative and technical aspects of the process, as well as the use of the eSourcing platform. The following topics were addressed:UNOPS and its function: Roles, functions, and guiding principles.UN Register of Suppliers: Registration in UNGM and bid announcements.UNOPS eSourcing System: Navigation, sections, information on the Request for Quotation, and related documents.Scope of the Invitation to Bid: Main objectives and requirements.Bid Submission: Procedures and guidelines.Communication methodology with UNOPS: Managing clarification requests from bidders, UNOPS responses, and addressing clarification requests from UNOPS during the evaluation process.Technical Overview: General technical presentation of the requirements.4. Submitting Clarification RequestsAs stipulated in the Invitation to Bid documents, attendees were informed that all inquiries or requests for clarification must be formally submitted through the "Request a Clarification" option in the "Tender Information" section of eSourcing, which serves as the sole communication channel for this process.5. Importance of Thorough Bid PreparationAttendees were reminded of the importance of carefully reviewing, analyzing, and considering all information provided in the bidding documents and the eSourcing system when preparing their bids.Barbados, April 15, 2026.
Edited on:
16-Apr-2026 19:16
Edited by:
webservice@unops.org
New clarification added: Clarification Note No. 2Dear Sir/Madam,In reference to the Invitation to bid ITB/2026/61229 for provision of Medical Devices - High Complexity for UNOPS in the Caribbean and for the Queen Elizabeth Hospital. In this regard, we are issuing this Clarification Note No. 2, which should be considered when preparing your bid.Question No. 7: We seek clarification regarding the “Requested Brand” mentioned in certain lots (e.g., Mindray, Steris, Valleylab).Requested Brand Only applies to: Lot 1 → Mindray, Lot 3, 4, 5 → Steris, Lot 6 → Valleylab (Medtronic)Are bidders required to offer only the specified brands, or are equivalent products from other manufacturers acceptable if they fully meet the technical specifications?Answer: Please refer to Answer to Question No. 1 within Clarification note no. 1Question No. 8: Do you accept FCA or CFR incoterm?Answer: Please be advised that the Incoterms 2020 specified in the document Section II: Schedule of Requirements are DAP (Delivered at Place) for the First Call Off Order to Barbados and FCA (Free Carrier) for subsequent Call Off Orders. Offerors are required to submit unit prices for both FCA and DAP.Question No. 9: Do you accept external registered companies outside your country to participate and to be equally evaluated with local registered companies?Answer: Yes, UNOPS accepts offers from companies registered outside the country of operation. Per the eligibility requirements, no nationalities are excluded from submitting a bid. UNOPS is committed to providing all potential suppliers with equal access and a fair opportunity to compete.Question No. 10: Will importing and customs clearance be done under UNOPS name in your country?Answer: As per Section II (Schedule of Requirements, Part C) and the Comparative Data Table, please note the following delivery instructions:First Call-Off Order (DAP): Delivery shall be made to The Queen Elizabeth Hospital, Martindale’s Road, St. Michael, BB11155, Barbados / UNOPS. Subsequent Call-Off Orders (FCA): Specific delivery and consignee information will be provided within each individual Call-Off Order.Question No. 11: We are distributor of many manufacturers but those vendors have no local representatives in your country. So would you accept shipping you the items and full process of customs clearance to be done under your name?Answer: Please be advised of the following regarding shipping, customs, and delivery for this solicitation:1. First Call-Off Order (DAP Barbados):Consignee: The Queen Elizabeth Hospital (QEH) will be the designated consignee for the first order.Customs Clearance and Tax Exemption: As the goods are intended for a health-strengthening project in coordination with the Ministry of Health and Wellness, tax exemption will be granted by the beneficiary (QEH). UNOPS will designate a customs broker to facilitate the process.Supplier Responsibility: Under DAP (Incoterms 2020), the supplier remains responsible for all costs and risks associated with transit and delivery to the final destination at the Queen Elizabeth Hospital, excluding the payment of import duties and taxes covered by the exemption. This includes, but is not limited to, freight, insurance, and local transport to the hospital site.2. Subsequent Call-Off Orders (FCA):Pricing Requirement: Per the solicitation instructions, offerors must provide unit prices in FCA (Incoterms 2020) for subsequent orders.Shipping Instructions: For these orders, the specific consignee and shipping instructions will be provided at the time of the Call-Off issuance.Please ensure your financial proposal includes both the DAP price for the initial Barbados requirement and the FCA unit prices for the LTA duration.Question No. 12: Customs clearance for importing will be done from A-Z by the you and there will be 100% VAT except and customs fees except 100%. So nothing will be paid by the supplier?Answer: Please refer to Answer to question No. 11Question No. 13: Due to the technical specifications for this request and close date for the Long Term Agreement for the Supply of Medical Devices - Medium Complexity , we are requesting submission deadline to be extended to 31st May, 2026Answer: Please note that the submission deadline remains unchanged.Question No. 14: Our company would like to participate in this project. However, we noticed that specific brands are designated in the documents.Could you please advise whether the specified brands are mandatory? Would other alternatives that fully meet the requirements be acceptable?Answer: Please refer to Answer to Question No. 1 within Clarification note no. 1UNOPS
Edited on:
13-Apr-2026 03:56
Edited by:
webservice@unops.org
New clarification added: Question No. 5: a) Would you accept any origin even if not from the US continent ? b) Is installation needed ? c) Is local agent needed ?Answer No. 5: a) Please be advised that there are no general restrictions on the country of origin. However, please note that for certain lots, specific brands are required for standardization purposes: Lot 1, Lot 3, Lot 4, Lot 5, and Lot 6.b) Installation: For all items except Lot 6 (Electrosurgical unit), the supplier is responsible for unpacking, installation, and on-site testing/commissioning to ensure the equipment is operational and ready for use.c) Local Agent/Support: While a local agent is not a general eligibility requirement, if the supplier is not established in Barbados or the final destination country, they must provide post-sales services through an experienced company established in Barbados or the final destination country for all items except Lot 6. For Lot 6, the supplier must provide a mechanism for technical assistance but a local company is not explicitly mandated in the 'Type 2' service requirements.Question No. 06: Can also manufacturers of medical equipment participate directly in the tenderAnswer No. 06: Yes, manufacturers are permitted to participate directly in this tender. According to UNOPS policy, a 'supplier' can be either a distributor or the manufacturer of a product.
Edited on:
02-Apr-2026 15:16
Edited by:
webservice@unops.org
New clarification added: Clarification Note No. 1Dear Sir/Madam,In reference to the Invitation to bid ITB/2026/61229 for provision of Medical Devices - High Complexity for UNOPS in the Caribbean and for the Queen Elizabeth Hospital. In this regard, we are issuing this Clarification Note No. 1, which should be considered when preparing your bid.Question No. 1: Regarding the tender specification, we noticed that it is mentioned that "the image is a generic visual reference to the required item and does not represent a commercial product indication". However in the spec it indicates specific brands again. Could you please clarify whether the proposed model should be in accordance with the named brand, or the bidder is allowed to offer equivalent models?Answer:For Lots 1, 3, 4, 5, and 6:Please be advised that for these specific lots, the brand and model indicated in the tender documents are mandatory. To ensure the successful enhancement of surgical capabilities and safeguard project impact, technically equivalent models or brands will not be accepted.This requirement is based on the beneficiary’s critical need for technological standardization and operational continuity within their existing installed base of medical equipment. Adhering to the specified brand allows the Queen Elizabeth Hospital to:- Ensure Operational Continuity: Both technical and clinical personnel are already specialized, trained, and certified in the specific operation and maintenance of the requested brand.- Streamline Maintenance: Utilizing a single brand ensures immediate equipment uptime, as staff are already familiar with the specific mechanical and software requirements.- Optimize Logistics: A unified inventory of interchangeable spare parts prevents delays in critical surgical care and streamlines inventory management.Consequently, all bids for these lots must strictly adhere to the brand and model indicated. Any offer of an "equivalent" model will be deemed non-responsive for these specific items.For All Other Lots:For all remaining lots not specified above, bidders may propose any brand or model, contingent upon full adherence to the established technical criteria.Question No. 2: We are currently reviewing ITB/2026/61229 and, during our assessment of Section II – Schedule of Requirements, we note that several lots include references to a “requested brand” and, in some cases, a specific manufacturer and model. We kindly request clarification on whether these brand and model references are intended to be mandatory requirements, or whether UNOPS would consider technically equivalent equipment from other manufacturers, provided that all minimum technical, clinical, certification, training, and after‑sales service requirements outlined in the ITB are fully met. In addition, if equivalent products are acceptable, we would appreciate guidance on the expected approach for demonstrating technical equivalency during the evaluation process.Answer: Please refer to Answer No. 1Question No. 3: We note that particular brands have been specified for most items. We request clarification on whether this is a brand-specific tender, or if alternative brands that are a 100% technical match would also be acceptable.Answer: Please refer to Answer No. 1Question No. 4: Please indicate whether Request Brand as per technical requirement is mandatory?Answer: Please refer to Answer No. 1UNOPS
Edited on:
31-Mar-2026 20:45
Edited by: