Supply and delivery of Lab equipments (Part VIII) to the Republican Specialized Scientific and Practical Medical Center of Oncology and Radiology in Tashkent, Uzbekistan.
UNOPS
Supply and delivery of Lab equipments (Part VIII) to the Republican Specialized Scientific and Practical Medical Center of Oncology and Radiology in Tashkent, Uzbekistan.
Request for quotation
Reference:
RFQ/2025/56754
Beneficiary countries or territories:
Uzbekistan
Registration level:
Basic
Published on:
19-Mar-2025
Deadline on:
29-Apr-2025 13:00 0.00
Expired
Description
This RFQ refers to the supply and delivery of Lab equipments (Part VIII) to the Republican Specialized Scientific and Practical Medical Center of Oncology and Radiology in Tashkent, Uzbekistan. The requirement includes the following item:
- Glucose analyzer (Glucometer)- 30 Pcs
- Urine centrifuge, benchtop- 2 Pcs
- Centrifuge, benchtop, includes swivel-tilt and various fixed angle and microplate rotors and inserts- 2 Pcs
- Incubator, variable temperature- 2 Pcs
- Fibrinometer -1 Pcs
- Magnetic stirrer- 2 Pcs
- Machine for mechanical coating of slides- 3 Pcs
- Water bath, electrothermal, boiling- 1 Pcs
- Water bath, electrothermal, shaking- 1 Pcs
- Compound microscope- 26 Pcs
- Mixer, emulsifier for laboratory, electric, bench-1 Pcs
- Cutter, hot wire-1 Pcs
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Sustainable resource use
Environmental
The tender contains sustainability considerations promoting the sustainable use of resources.
Examples:
Energy-saving measures, recycling, take-back programmes and responsible end-of-life management
| Link | Description | |
|---|---|---|
| https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
New amendment added #1: Extension of tender deadline by 7 Days.
Edited on:
17-Apr-2025 14:50
Edited by:
webservice@unops.org
New clarification added: Q 14. As 1 Lot includes 12 separate items, each requiring a completed technical specification form and a corresponding set of supporting documents, we kindly request a deadline extension of by at least 2–3 weeks. This additional time would allow us to carefully prepare the documentation and ensure the proposal fully complies with the tender requirements. We would be grateful for your kind consideration and look forward to your response.A 14. UNOPS is strongly considering extension of the tender by two weeks. Q 16. For item#4 Incubator, please kindly note that Standard required DIN EN12880 refers to“Characterization of sludges - Determination of dry residue and water content; German version EN 12880:2000”, which is not applicable for Incubator. Please clarify if CE certificate in accordance with EN61326 could be considered?A16: The standard DIN EN12880 remains unchanged by the request of the beneficiary. Q 17. For Item#5 Fibrinometer, it is required: “The system shall provide panoramic scanning in greyscale, allowing the acquisition and display of images up to 240 cm long”, please confirm if the image’s length 240cm±15% is acceptable?A17: Yes image’s length 240cm±15% is acceptable.Q 18. For Item#9 Water bath, it is required: Input voltage: 110V, 60HZ, please confirm if 220V, 60HZ is acceptable?A18. Yes only 220V , 60Hz is acceptable. In Rep Uzbekistan the standard is 220V. Q 19. For Item#12 Cutter, Hotwire, it is required: Length up to (500mm), Diameter up to (180mm), please confirm if length 500mm±5%, Diameter±15% could be acceptable?A19. Yes we do confirm length 500mm±5%, Diameter±15% is acceptable.Q 20. Regarding Item No. 6 – Magnetic Stirrer/Vortex:The technical specifications mention that the device should be capable of working with standard tubes, flasks, beakers, micro-tubes, and micro-plates.Typically:A vortex mixer supports tubes and micro-tubes.A magnetic stirrer supports flasks and beakers.Since the description includes features related to both devices, could you please confirm whether both devices are required, or if one device with combined functionality is expected?A 20. A device with combined functionality is expected. Q 21. For Item#9 Water Bath, it is required: Temperature range of at least 5°C to 100°C. please confirm it is on basis of ambient temperature ? i.e. ambient temperature+5℃~100°C?Maany thanks.A21. Temperature setting range in the device must be at least 5°C to 100°C.
Edited on:
15-Apr-2025 15:02
Edited by:
webservice@unops.org
New clarification added: Q. 12 Lot 12 RFQ reference no: RFQ/2025/5675.Technical form D.Items 15-16.15.Power 115 VAC @ 50/60 Hz (2.5A)16.Optional Voltage 230 VAC @ 50/60 Hz (1.25A)In most cases, in power supply standards, the built-in voltage is 220 V, and the optional voltage is -115 V. The devices you are requesting also have a voltage of (220 V). In this regard, I ask you to correct the technical specification.A. 12 Yes the requirement is 220 V not 115 V . It will be corrected in the specification. Dear Evaluation Team,Q 13. We would like to request a clarification regarding the Item No. 12 - Cutter, hot wire. Could you please clarify the specific purposes or applications for which it will be used, so that we can offer the most suitable equipment?A.13. It will be used mainly for cutting plastic bottle type containers.
Edited on:
15-Apr-2025 10:14
Edited by:
webservice@unops.org
New clarification added: Q 11. Often manufacturers in China are one company, and those engaged in the supply and assembly of parts are other companies. In this regard, in the announced lot for the supply of microscopes, we wanted to offer products from a manufacturer from China. Since the manufacturer of the main part of the microscope is one company, and the supplier is another company, could we provide ISO and CE certificates, as well as an authorization form from the manufacturer?A 11. Supplier can provide ISO and CE sertificates, if they have authorization from the manufacturer for supplaying manufacturers products.
Edited on:
15-Apr-2025 10:06
Edited by:
webservice@unops.org
New clarification added: Q 10. would like to inquire if we can participate with only one item, the Glucose Analyzer (Glucometer), for a quantity of 30 pieces, out of a total of 12 items in the procurement process.A10. Unfortunatelly, partial bids are not accepted for this tender.
Edited on:
10-Apr-2025 12:30
Edited by:
webservice@unops.org
New clarification added: Q9. We are writing to kindly request clarification regarding Item No. 5 – Fibrinometer (1 Pc) mentioned in the document.Could you please confirm the exact requirement and clarify whether it refers to a FibroScan Machine or an Ultrasound Machine?A9. This mashine is for ultrasound diagnostic system. only for liver diseases diagnostics (Fibrosis scanning equipment ) not general ultrasound equipment.
Edited on:
09-Apr-2025 10:49
Edited by:
webservice@unops.org
New clarification added: Q 8: I would like to seek clarification regarding Item No. 12.Could you kindly confirm if the dimensions mentioned at point B13 (180mm H x 650mm W x 550mm D) refer to the machine's size? If these measurements are for the machine, it seems to be a small unit that would need to be placed on a table or desk.Additionally, could you please let us know what type of bottles need to be cut? If possible, do you have a sample image of these bottles?A8: Yes it can be placed on a desk. Bottles can be a different shape and size from plastic or soft matherial within the dimention described.
Edited on:
07-Apr-2025 15:01
Edited by:
webservice@unops.org
New clarification added: Q3. . In view of 2 or 3 lab equipment within the 12 items, up to now, no suitable products have been found, could you kindly clarify if the partial bid is acceptable ?A3. Not in this tender partial bid is not acceptable.Q4. For Item#1 Glucose analyzer (Glucometer), it is required: "Sample type: capillary, venous, arterial". Usually, blood from capillaries or venous blood is enough to be drawn to analyze blood glucose levels, arterial blood is not necessary to be drawn. Please confirm this point. A4 : Please confirm this point. Capillary is enough. "Sample type: capillary, venous, arterial." to be changed for Sample type: capillary and/or venous and/or arterial.Q5. For Item#2 Urine centrifuge, benchtop, it is required: "Approximate acceleration time: 10 sec", please confirm if acceleration time: 30 sec is acceptable ?A5: No. acceleration time 30 sec is not acceptable. Q6. For Item#7 Machine for mechanical coating of slides, it is required: "Lids come in different covers for solvents and staining fluids", please confirm if is acceptable lids with same covers for solvents and staining fluids (If the user needs to distinguish, it should be labeled when using.)A6: Not it is not acceptable. lids must be with different covers and staining fluids.Q7. For Item#12 Cutter, hot wire, please confirm it is used for cutting the plastic bottles. A reference photo will be preferable to be shared.A7: Yes we confirm that this is to cut plastic bottles. Sample Image provided here : https://drive.google.com/file/d/1DAC8rIEXziPgYxbxoT-uAcTqQi7TzkRr/view?usp=drive_link.
Edited on:
03-Apr-2025 14:31
Edited by:
webservice@unops.org
New clarification added: Q2 : clarification regarding Item No. 1 – Glucose Analyzer (Glucometer), Sr. No. 11, specifically under the "Dose Detection" section.Could you please provide further details or explain the requirements/criteria for this feature?A 2: By "Under Dose detection" in a glucometer it is refered to the device's ability to detect and verify an insufficient blood sample.
Edited on:
25-Mar-2025 14:10
Edited by:
webservice@unops.org
New clarification added: Q1: Are international companies eligible to participate in this tender? A1: As per the Particulars of the RFQ, the bidder may have the nationality of any country, therefore international companies are eligible to participate in this tender.
Edited on:
20-Mar-2025 07:53
Edited by:
webservice@unops.org