Description
Tender description: Construction of NAP/NMCP Warehouse in Yangon, Myanmar
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Gender issues
Social
The tender contains sustainability considerations addressing gender equality and women's empowerment.
Examples:
Gender mainstreaming, targeted employment of women, promotion of women-owned businesses.
Prevention of pollution
Environmental
The tender contains sustainability considerations for the prevention of polluting emissions to air, solid waste to land and discharges to water.
Examples:
EMS, waste management and wastewater management.
Link | Description | |
---|---|---|
https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
72121403
-
Hospital construction service
Tender cancelled on 2021-08-30 08:54 UTC. Dear Bidder,We would like to inform you that the tender was cancelled due to the current political situation in Myanmar. We would like to thank you for the time and effort spent in submitting your offer and assure you that the fact that you have been unsuccessful on this occasion will not affect any offers you may make in any other procurement process with UNOPS in the future. We encourage you to regularly review the procurement notices published on the UNOPS website and the United Nations Global Marketplace (www.ungm.org) for procurement opportunities with UNOPS and other United Nations organizations.Best regards,MMOC Procurement Unit.
Edited on:
30-Aug-2021 10:54
Edited by:
webservice@unops.org
New clarification added: Q: Our main contractor hasn’t received the activation link to access UN Global Market although it has completed new registration. Please kindly assist to receive activation link.A: The activation link has been received and activated now, we think. Because we found your main contractor in UNGM, we can send the invitation to them through eSourcing system and they expressed interest. Q: Furthermore, due to the protests and unrest situation in Myanmar, most suppliers are not working at this time and we are having difficulties to get pricing back from suppliers. Therefore, we would sincerely like to request further extension of time for ITB/2021/18760 & ITB/2021/18711.A: The tenders had already extended to 8th of March 2021 for 10 days and will not be extended further.
Edited on:
03-Mar-2021 11:55
Edited by:
webservice@unops.org
New clarification added: 1- 300x300mm Precast RC pile and axial capacity 90 Tons –Q: We quested Pile manufacture SCG to check the pile capacity as shown in Structure Drawing No. SO-04. 300x300mm RC pile with 4-DB20 main reinforcement. Concrete grade G40, Rebar 400Mpa. Based on these data, allowable pile capacity is only 69 tons. Can't get 90 tons as specified at BOQ Item 6.Please clarify.A: This was aquired through structural analyis of the design of piles. It can be verified through testing during construction.2- Relocation of TreesQ: In the drawing A1-01, 12 Nos. of existing trees need to be relocated. But when we check on site, these trees are too big to relocate and can't survive after relocation. Therefore, instead of relocation, we propose to remove existing trees and to plant new trees.A: This is operational issue and shall be decided during implementation.3- Soil ReportQ: Kindly provide Soil Report.A: Please find the Soil report (Geotechnical Investigation Report) under documents section. The report will not be part of the contract and the Employer does not warrant and shall have no responsibility or liability whatsoever for the accuracy, sufficiency or completeness of the soil report, or any information given. The bidder shall not rely on and shall be deemed not to have relied on any site data provided by the Employer and the Employer shall not be liable to the Contractor or any third party (whether or not arising out of any negligence on the part of the Employer or any agent or servant thereof) in respect of any inaccuracy, error, omission, defect or inadequacy of the report. 4- Welding Test UT/RT is specifed in specification 12.5.5. But it is not included in BOQ item 12 structural steel.Q: Should Welding Test cost be included in BOQ Item 12 unit rate?A: There will not be a separte rate for testing. As indicated under sub-clause 4.9 of the contract, the Contractor shall institute a quality control system to demonstrate compliance with the requirements of the Contract. In this case the contractor has to proof that his welding complies to the requirement through testing at his own cost.
Edited on:
03-Mar-2021 09:16
Edited by:
webservice@unops.org
New amendment added #3: The ITB is hereby amended as follows;The updated Annexure 3-BOQ V1 which corrected the typo error was uploaded under documents section.Geotechnical Investigation Report was uploaded under documents section.
Edited on:
03-Mar-2021 09:03
Edited by:
webservice@unops.org
New clarification added: Q: In drawing NAP/NMCP -F5-04, we found that fire water tank and accessories but not mention in BOQ. Please clarify.A: The civil works for fire water tank is included under BOQ items 9.2 and 10 and the electrical and mechanical are included under BOQ item 29.Q: For NAP, please describe existing capacitor bank (30 kVAR) location. Please clarify.A: Please refer to NAP/NMCP-E1-01 for the location of 30kVAR capacitor bank and MDB-1. and Contractor shall follow the design of MDB-1+CAP as per NAP/NMCP-E1-01.Q: For NMCP, in Fire Alarm System, cable description at schematic diagram and notes is not match.Please clarify cable size. A: Please refer to NAP/NMCP-E2-04 the fire alarm system schematic diagram and notes that are matched with each other. Q: For CCTV System, please describe recording times. Please provide.A: The recording time for the DVR shall be 30 days.Q: In Electrical system drawings, there is no Cable Tray and trunking Layout Plan although describe in detail drawing. Please describe this drawing.A: The selected bidder shall submit a working drawing for the cable tray and trunking layout as per site condition during construction stage for the employers approval.Q: Concrete pole height is different between BQ (10m) and detail drawing (12m). Please clarify. A: Bidder shall offer price for poles as indicated in the drawing.Q: For MDB1 & MDB2, panel design is with separate or partition. Please provide.A: Contractor will submit Panel Design during construction stage according to Manufacutrer's recommendation for the proposed panels.Q: Please clarify Generator fuel Tank capacity. Please provide. A: Supply of a separate fule tank is not included in the scope. The Contractor shall propose a generator with build in fuel tank and complying with the requirements. Q: For construction period , temporary electricity is from existing source or generator. Please clarify.A: Selected bidder has to agree with the MOHS during construction for the usage of exisitng electricity and payment of bills for temporary works or can use its own geerator if this is preferable.Q: For existing store buildings demolishing work, how to terminate the main connection of electric cable after removing works. Please clarify. A: Bidders has to prepare method statement for the works. For this particular work, the activity shall be done in consultation/collaboration with Myanmar electric power enterprsie.
Edited on:
02-Mar-2021 13:12
Edited by:
webservice@unops.org
New clarification added: Q: We didn’t find the fire hose reel schedule and fire fighting system specification. Please provide detail specification.A: Bidder shall refer to NAP/NMCP-F2-01 and NAP/NMCP-F7-03 for fire hose reel system.Q: We found Air grille schedule and power accessories schedule for Air conditioning system in technical specification but we didn’t find in drawing . Please clarify.A: Please refer to NAP/NMCP-M3-01 & 02 for air grille and NAP/NMCP-M6-03 & 04 for power supply drawing of Air Conditioning sytems.Q: We found that Water treatment system for drinking water so do you have any pre filtration system before drinking water system. Could you provide raw water quality ?A: There is no prefiltration system. The water quality test shall be carried out by the selected bidder during construction.Q: We Found that Air Conditioner at existing Building so we need to maintain and repair for existing AC . If you considered this Air Conditioner repair works, would you advise to add in which item of BOQ ?A: Repairing the exisitng AC is not part of the scope of the work and bidders should not add any BOQ item to the tender BOQ.Q: We found that existing water pump room Q- 4 Cum/hr and 32m Head in P&S site plan drawing no NAP/NMCP -N1-01 but mention existing water pump 01 -2.5 cum/hr & 30m Head and existing pump 02 – 2 Cum/hr & 25m Head in drawing no NAP/NMCP -N0-01 . Please clarify. A: As per Drawing NAP-NMCP-N1-01, Contractor shall supply Q=4 Cum/Hr and H=32m Stand by and Duty Pump in existing pump rooms. NAP-NMCP-N1-01 clearly indicates that existing pumps are Q= 2.5Cum/Hr and H=30m and Q=2 Cum/Hr and H=25m for existing water supply system.Q: In drawing no NAP/NMCP -F2-02 , (FIRE PUMP AND FIRE PUMP CONTROLLERS SHALL BE PSB LISTED AND/OR UL LISTED AND/OR FM.APPROVED), but suppliers not provided PSB Listed, UL/FM Approved for fire hose reel pump. Please advise. A: Contractor shall request approval of proposed fire fighting pumps during implementation as per Myanmar Standards.Q: In detail drawing no NAP/NMCP -F7-03, we found fire extinguisher with cabinet. Please clarify need to consider extinguisher cabinet.A: Bidders shall follow the detail specification of fire extinguishers as per NAP/NMCP -F7-03.Q: We found the roof drain in the plan drawing (NAP/NMCP-N3-04), but not mention in the BOQ. Please clarify.A: Please refer to BOQ 28.5 for roof drain worksQ: According to site visit , we found the water supply line pass through existing building. This supply line is not suitable in construction stage. Please Clarify.A: The water supply pipe line has to be relocated and the cost of this shall be included in the BOQ Item 2- Site preparation works.Q: Source of water (from Tube well) and sewage disposal (existing septic tank) for temporary are sufficient to provide or not. Please Clarify. A: The temporary water needs and the temporary toilets and spetic tanks has to be arranged by the selected bidder during constructionQ: Please clarify to provide water pump room for new booster pump near existing water tank. Please clarify.A: Please refer to the drawing NAP-NMCP-N1-01. It is stated that booster pump has to be installed in the exisitng pump room.
Edited on:
02-Mar-2021 13:03
Edited by:
webservice@unops.org
New clarification added: Q: Item ref 19.3, Insulation for Type W5 wall is mentioned as 80mm thk fiberglass Insulation in material schedule. As the fiberglass thickness is producded 25mm & 50mm thickness in market. Can we use the 50mm thk fiberglass insulation of SCG Brand? A: Bidder has to offer price as indicated in the BOQ and drawing. If needed this will be decided during implementation after assessing the impact of changing the thickness and avilability both in local market or neighbouring countries.Q: For Construction, Water supply for construction project is not enough to be used. Can we get the permit to make water tube well?A: There is an exisitng tube well and the water supply suffecient for the works. However, if the bidder wants to drill its own well for the construction purpose, this has to be done with out extra cost to the employer. The necessary permits shall be furnished during construction.Q: For Roofing Work, One existing building roof is clay tile roofing. In drawing, the same hatch pattern of exisitng roofing type is mentioned. If we make the renovation and extension works, the clay tile roofing will be demaged. Can we install new 4 angle sheet roofing instead of clay tile roofing?A: The new roofing is independent of the exiting roofing and there is no renovation work of the exisitng roofing syatem. The roofing shall be made as per the design drawings. Q: For Tree Relocation Work, If the tree is died after relocating work, what size of tree need to plant instead of this tree. Please provide us.A: This will be decided during implementation. However, the selected bidder has to exercise maximum care during relocating of the exisitng trees.Q: For Fire Water Tank, The civil work for fire water tank is included in concrete and rebar work.What item of BOQ will the cost for SUS ladder of fire water tank be added?Please provide us. A: The BOQ for civil work shall be inclusive of all associated civil items.Q: PVC Pipe’s pressure for sewage system mentioned 12bars in specifications and Class 8.5 in BOQ. Please clarify which one is confirm.A: Bidders shall follow the BOQ requirments. The technical specification is standard.Q: HDPE Pipe’s PN rate for sewage system mentioned PN8 in specifications and PN10 in BOQ. Please clarify. A: Contractor should follow the drawing number NAP/NMCP-N0-02 and BOQ according the location of usage.Q: We found that the water heater in specifications, but not found in the drawing. Please clarify.A: Hot water system is not included in this project.Q: We found that the sink mixer tap for basin (In BOQ, Item Ref.23.2) but not found in the drawing. Please clarify.A: Please follow the sanitary fixuters specification as per A9.02.Q: Please clarify Booster Pump Pressure Tank capacity. Please provide pressure tank size.A: Contractor shall follow the Water Distribution Systsem as indicated under drawing number NAP/NMCP-N0-01.Q: We found that water meter pit in Specification Pg 269 but not mention in BOQ. Please clarify to add in which item.A: Water meter pit is not required for this contract. The technical specification is standard specification and some work items may not apply to this project.Q: We found that Vertical Multistage Variable speed booster pump in detail drawing no NAP/NMCP -N7-01, but mention constant speed type in BOQ. Please clarify.A: Bidder shall offer price for the booster pumps specified in Drawing number NAP/NMCP-N7-01.
Edited on:
02-Mar-2021 12:52
Edited by:
webservice@unops.org
New clarification added: Q: Is W5 (Stud Wall) the same Cold Room (prefabricated) insulated panel wall. Because Cold Room Wall item is not included in BOQ.A: W5 is a gypsum pannel stud wall at the meeting room (Drawing A2-03) and is not the same as the cold room. Please refer to Archi Drawing No A5-02 for cold room details. Cold room wall is included in the BOQ Item 30.5.1.1.Q: In BOQ item 22.2.2, 300 mm height polished cement and paint finish with water proffing unit is m2, please clarify m2 or m.A: The unit of measurement for BOQ item 22.2.2 is m2.Q: In fire fighting drawing , fire tank and pump room is included but not included in BOQ . Please clarify.A: All quantities of structural members for fire fighting are included in BOQ items 9.2 and 10.
Edited on:
25-Feb-2021 15:02
Edited by:
webservice@unops.org
New clarification added: 1) Anti-termite Treatment ChemicalQ: Chemical names Aldrin, Heptachlor & Chlordane are stated in the specification. But these all chemicals are banned in Myanmar.Therefore, can we proposed alternative chemical for anti-termite work?A: Yes, alternative chemicals complying to the requirment will be accepted and to be decided during implementation.2) Concrete Road ThicknessQ: There are two type of pavement/road in the Drawing No C2-01, 150mm thk and 200mm thk. In the BOQ Item 13, there is no specification for Road thickness. Please clarify thickness of Pavement/Road for BOQ Item 13.A: The slab thickness is 200mm as the pavement is going to accomodate trucks that load/unload goods .3) Drain SizeQ: In the Drawing C4-01 shown two size of drains, 300mm drain and 600mm drain.In the BOQ Item 15, there is only 600mm drain. Please clarify.A: Bidders shall quote as per the sizes indicated in the Structural drawing C4-01-Surface water drainage plan.4) Drain Cover TypeQ: In the Drawing C2-01 shown 3 types of drain covers. Heavy duty/ Light duty R.C Cover and Heavy duty Steel Cover.But Location of drain covers are not shown in the drawing /plan. Therefore, please provide heavy duty & light duty drainage cover length separately.A: The cover shall be heavy duty steel cover as indicated in the legend of the drawing C4-01.5) Apron reinforcement.Q: In the Drawing No C4-01, Apron is shown as 50mm plain concrete slab. In the BOQ Item No.14, describe as .......Cost to include sand compacting, formwork fixing, rebars, concreting,…. Please clarify that can we price for Apron as plain concrete slab as shown in the structure drawing C4-01?A: The apron is plain concrete and shall be as per the drawing S0-02: 50mm thk plain concrete and 50mm thk well compacted sand. Cost shall include the concrete, well compacted sand beds and assocated form work and materials.
Edited on:
25-Feb-2021 12:24
Edited by:
webservice@unops.org
New clarification added: Question: I have aware that we have came across to the tender invitation a bit late and are wondering whether further tender extension is possible by request. Answer: The tender is already extended to 8th of March 2021 and will not be extended further. we believe that the time given is suffecient for bidders to prepare and submit offers.Question: Understood the project is only one contract (Main Contract), in that case, may we, as M&E contractor, be allowed to submit on behalf of Main-contractor or may Main-con may register on esourcing. Answer: Main contractor that is submitting the bid shall be registered and all other sucontractors shall be indciated in Returnble Bid schedule -12.Question: Is there any chance that tender may separate for C&S and M&E, then to provide only M&E quote? Answer: As indicated in Instruction to Bidders caluse 14 of the tender- Bidders shall respond to all applicable Returnable Bid Schedules and shall bid for all sections of the works. UNOPS will NOT accept bids for one or several sections of the works only, nor will UNOPS accept bids for only part of the works or part of any section of the works. However, main bidder can subcontract specific and specialized work items and the subcontractors shall be indicated clearly under returnble Bid schedule -12.
Edited on:
25-Feb-2021 12:14
Edited by:
webservice@unops.org
New clarification added: 8- CCTV System; BOQ Item 34.1 & 34.2Q: Recorder is DVR type (analogue system) and cable is cat 6 (digital system).Which system we will follow digital or analogue?A: CCTV is analogue. Cable and other associated aceessaries shall be as per manufacturere's recommendations.9-Multi blade Volume Dampers- BOQ Item 30.2.19 to 30.2.20(Ducting System)Q; Does Multi blade Volume Dampers mean Volume Control Damper? If not, please provide the size for Multi blade Volume Dampers.A: Yes, it is volume control dumper.10- Cold Room System: BOQ Item 30.5Q: 1) Monobloc item means Cold Room Refrigeration Unit or brand name? 2) Monobloc 30 m3 unit means volume of cold room? 3) Which product for cold storage? 4) Product Load: (kgs/day)? 5) (+2°C to +8°C) means to maintain temperature within (+2°C to +8°C)?A: 1. It is not brand name. It is coldroom system complete with panel insulation, floor,door, wall and roof panel construction, shelving, lighting, alarm system, temperature monitoring system, spare part, refrigration units, including associated works complete.2. 30m3 is the volume required to store the vaccines3. The type of product shall comply with the specified requirments and will be decided during implementation and no brand is specified at the moment.4. This depends on the proposed brand and will be approved during implementation5. cold room internal temperature to maintain t+2°C to +8°CRefer to the following link for an example informationhttps://supply.unicef.org/s0005160.html11 - Method of Measurement: GCC 12.2Q: Please specify the method of measurement such as NRM, SMM etc.A: "Measurement shall be made of the net actual quantity of each item of the Permanent Works as speficied in GCC 12.2 ; andthe method of measurement shall be in accordance with the method specified in the Schedule 7- Schedule for Contract Price.'12 -BCC (Building Completion Certificate): BOQ Item 2.0Q: Is BCC Building Completion Certificate included in contractor's scope of work?A: Yes, it is the responsiblity of the contractor if required by YCDC. However, UNOPS, the Client and the contractor will also carry out joint inspection and UNOPS will issue a completion certificate after completion of the work.13-Detail Break-down Cost Format: Annexure 3- Note - Price Preambles - Item 7Q: Please provide standard Detail Breakdown Cost Format.A: This is basic engineering and each bidder may have its own approach and template and UNOPS will not provide format. The bidders when requested shall provide the cost breack down of a BOQ item and shall include Labor cost,material cost,equipment cost,overhead cost and profit.
Edited on:
24-Feb-2021 09:28
Edited by:
webservice@unops.org
New clarification added: 1-Warranty for Anti-termite treatment: BoQ (No.4)Q: Please clarify warranty for Anti-termite treatment such as 3 years, 5 years etc.A: Please refer to chapter 25 of the standard technical specification for Anti termite treatment.2 - Pile Load Test - BoQ (No.6)Q: For (12"x12”) Precast Pile, which types of pile load test & how many percentage of total pile points for each load test need to provide? Please clarify.A: Please refer to technical specification clause 2.7 for detail specifications of the piling work and refer. Testing can also be as required by CQHP for driven piles. Please also note that each pile should have axial capacity of 90 Tons as specified in the Item BOQ - 6.3 - Door D08 & D09 - Drawing No. A7.02 & BOQ item no. 17.3.2 & 17.3.3Q: In drawing no. A7.02 (Door schedule) - D08 & D09 are described as Timber Doors. In BOQ item no. 17.3.2 & 17.3.3 - D08 & D09 are described as Aluminium Doors with Laminated glass. Please clarify.A: Please quote the pirces for D08 & D09 as timber doors including all necessary fixings and accessories as shown in drawing no. A7.02 as the drawing has precedence over the BOQ.4- Insulation of Wall Type (W5): Drawing no. A9.03 (Architectural Material schedule)Q; In drawing no. A9.03 (Architectural Material schedule) - Stud Wall's insulation for Wall Type (W5) is described as 80mm thk; Fiberglass Insulation.A: W5 is 150mm thk; wall with 12.5mm thk; gypsum plaster board in both sides and 80mm thk; fiberglass insulation in the middle of wall. Please refer to drawing no. A8.02 and A9.03.5-Unit of BOQ Item 33.14.4 : BOQ Item 33.14.4 IEC01 for emergency light and exit sign (240-Set)Q: In BOQ Item 33.14.4, Unit of 1.5 mm2 IEC01 for emergency light and exit sign is ‘"set”. Please clarify the unit, set or m (Running meter)?A: It is typo error the unit is 240meter.6-Earth Cable Size - BOQ Item 33.16.5, 1200mm² PVC/PVC grounding cable; Drawing No. NAP/NMCP-E2-03, 120mm2 PVC/PVC grounding CableQ: Earth cable size is difference between BOQ & drawing. Which item do we follow BOQ or drawing. Please kindly clarify 1200mm² PVC/PVC or 120mm² PVC/PVC?A: It is typo error and in electrical cable the size 1200mm2 is not practically available. Please refer to Drawing NAP/NMCP-E2-03 and the cable size is 120mm2.7- AVR- Drawing No.NAP/NMCP-E1-01Q: In the Drawing No.NAP/NMCP-E1-01, AVR is included but not included in BOQ & LV Power System Schematic for NAP drawing. Is AVR included in the bidder's scope or not? Please clarify.A: AVR is not required and not included in the bidder's scope of work.
Edited on:
24-Feb-2021 09:02
Edited by:
webservice@unops.org
New clarification added: Q: According to meeting 17 February 2021, is extension date confirm 7 March 2021?We are here to waiting for our clarification reply in1) Submission deadline extension,2) Clarifification deadline extension.A: We have agreed and extended the submission deadline till 8.March.2021 and clarification deadline is extended till 3.March.2021.
Edited on:
19-Feb-2021 13:58
Edited by:
webservice@unops.org
New clarification added: 1- Type of Contract : Annexure 3- Note - SPECIAL CONCERNS - The contract shall be a Measure and Pay contract and ITB 7 mentioned. UNOPS LUMP SUM CONSTRUCTION CONTRACTQ: Please confirm the type of Contract A: Number 7 of the Section I Instruction to Bidder also referred to Section III which included as contract sample in the ITB, please be confirmed that the type of contract is Measured Price Construction Contract.2- Advance Payment : Schedule 8 - No Advance PaymentQ: We would like to request 15% advance payment.A: UNOPS will not give advance payement for this contract. 3-Permit: BOQ Item 2.0 x x x required permits and approval for construction from relavant local goverment authoritiesQ: Is YCDC Construction permit already obtained by client? Kindly clarify which permits are required to be obtained by the contractor.A: YCDC permit is not yet obtained. Slected bidder with the help of UNOPS and MOHS shall obtain all the required permits from YCDC during implementation.4- BOQ quantity: Annexure 3- Note - Price Preambles - Item 2 The quantities given in the Bill of Quantities are estimated and provisional, and are given to provide a common basis for bidding. The basis of payment will be the actual quantities of work ordered and carried out, as measured by the Contractor and verified by the Engineer ............Q: Please clarify what kind of break down need to submit. For example- BOQ Item 2 - SITE PREPARATION WORKS: To list down all the items cost (or ) To sepreate material, labour , machine cost?A: It is not required to submit the detail break down/rate analysis with this submission. The bidder shall submit the cost break down/rate analysis of each bill item when requested by UNOPS during bid evaluation or at a later stage.5- Detail Break-down: Annexure 3- Note - Price Preambles - Item 7 -The Contractor shall provide with his Tender submission a detailed breakdown of all priced items of Bills. This breakdown of the items shall be in a format, which also clearly identifies any "Set - Up", "Time Related" and "Dismantling Elements" of the costsQ: Please clarify what kind of break down need to submit.A: It is not required to submit the detail break down/rate analysis with this submission. The bidder shall submit the cost break down/rate analysis of each bill item when requested by UNOPS during bid evaluation or at a later stage6- Site Vist: Q: To check eisting services, renovation and demolitation work, we would like to request site visit.A: Site visit is applicable as details mentioned in the tender particular section.7- Q: Submission deadline date extension in previouse request.A: We have agreed to extend until 8th of March 2021 in relation to the current crises and frequent inturuption of intenet and difficulty in collecting market prices.
Edited on:
19-Feb-2021 13:50
Edited by:
webservice@unops.org
New clarification added: Question: I would like to request the extension date of the ITB/2021/18760 -Construction of NAP/NMCP Warehouse in Yangon, Myanmar. Is there any opportunity to get the extension to do the submission given the deadline to be on 25th Feb 2021 which dates so soon during this period of critical political situation.Answer: We have extended until 8th of March 2021 in relation to the current crises and frequent interuption of intenet and difficulty in collecting market prices.
Edited on:
19-Feb-2021 13:26
Edited by:
webservice@unops.org
New amendment added #2: The ITB is hereby amended as follows;Deadline for submission has been extended by 11 days to 8.March.2021 at 3:00 PM Myanmar Standard Time (8:30 UTC) and deadline for clarification has been extended till 3.March 2021 at 12:00 Noon Myanmar Standard Time (5:30 UTC).Pre-Bid Meeting Minutes and Power Point Presentation were attached in document section.Site Visit/Inspection is applicable as details mentioned in tender particular section, but it is not mandatory.
Edited on:
19-Feb-2021 05:44
Edited by:
webservice@unops.org
New amendment added #1: Dear Sir The ITB/2021/18760 is hereby amended as follows:The updated Annexure 3-BOQ is uploaded.
Edited on:
16-Feb-2021 11:58
Edited by:
webservice@unops.org