Construction Works for the Proposed Headquarters Building & Training Center for the Department of Customs, Premises of Ministry of Finance, Vientiane, Lao PDR
UNOPS
Construction Works for the Proposed Headquarters Building & Training Center for the Department of Customs, Premises of Ministry of Finance, Vientiane, Lao PDR
Invitation to bid
Reference:
ITB/2024/54786
Beneficiary countries or territories:
Lao People's Democratic Republic
Registration level:
Basic
Published on:
19-Nov-2024
Deadline on:
16-Dec-2024 07:00 (GMT 0.00)
Description
Tender description: ITB Construction Contract for Small Works - Construction Works for the Proposed Headquarters Building & Training Center for the Department of Customs, Premises of Ministry of Finance, Vientiane, Lao PDR
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
-----
IMPORTANT NOTE: Interested vendors must respond to this tender using the UNOPS eSourcing system, via the UNGM portal. In order to access the full UNOPS tender details, request clarifications on the tender, and submit a vendor response to a tender using the system, vendors need to be registered as a UNOPS vendor at the UNGM portal and be logged into UNGM. For guidance on how to register on UNGM and submit responses to UNOPS tenders in the UNOPS eSourcing system, please refer to the user guide and other resources available at: https://esourcing.unops.org/#/Help/Guides
Interested in improving your knowledge of what UNOPS procures, how we procure and how to become a vendor to supply to our organization? Learn more about our free online course on “Doing business with UNOPS” here
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
Link | Description | |
---|---|---|
https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
81101513
-
Building construction management
New clarification added: QUESTION: 1 set of electrical system security without piping in drawing, but in the BOQ is not exist?ANSWER: [Correction] Please be informed that electronic security system's cable is to be installed in wireways. See BOQ (not Drawings) Elecrtronic Security System 4.14.1 to 4.14.25
Edited on:
16-Dec-2024 05:08
Edited by:
webservice@unops.org
New clarification added: QUESTION: 1 set of electrical system security without piping in drawing, but in the BOQ is not exist?ANSWER: Please be informed that electronic security system's cable is to be installed in wireways. See drawings Elecrtronic Security System 4.14.1 to 4.14.25
Edited on:
16-Dec-2024 03:49
Edited by:
webservice@unops.org
New clarification added: QUESTION:# Retaining wall work at T.B 0+0001. Form installation: 3 skill workers, 4 workers2. Casting wall concreteANSWER:As clarified through email communication sent on 10 Dec 2024 since UNOPS did not understand and needed to clarify the question, the bidder raising this question informed us to ignore the question.
Edited on:
16-Dec-2024 03:31
Edited by:
webservice@unops.org
New clarification added: QUESTION:Refer to the piling size and quantity in group item No. 2.2.1 in the BOQ. There is also a Jack-in Pile (L=21m) of size 400mm x 400mm missing in drawing no. UNOPS-DD-CS-DG-1001. There are three group piles: P1 Group, size 400x400, depth 22.2 m; P2 Group, size 300x300, depth 22.2 m; and P3 Group, size 400x400, depth 17 m. Please clarify.ANSWER:The drawing No. UNOPS-DD-CS-DG-1001 shown plan of the jack-in pile. Detailed of the piles are shown in drawings No. UNOPS-DD-CS-DG-3004 and UNOPS-DD-CS-DG-3005. The boq no.2.2.1.1 has total number of piles 377 nos. Number of each pile P1, P2 & P3 can be found on the drawing no. UNOPS-DD-CS-DG-1001
Edited on:
11-Dec-2024 06:28
Edited by:
webservice@unops.org
New clarification added: QUESTION:* BOQ of the Structure Works (Bill 2)the amount of rebar work is included in the concrete work of each floor? * BOQ of the Architecture Works (Bill 3)item 3.12 (# Built-In), type of kitchen low and top cabinet has no details of sizes in drawing?item 3.6, the 600*600mm (Matt Finished) to be painted in gray of stone color, not paved? * BOQ of the Electrical Systems (Bill 4)item 4.14.8, IP Bullet Cameras 4 MPx by 3 sets, but in drawing it’d be 7 sets?item 4.14.9, PI Dom Camera 4 MPx by 2 sets, but in drawing it’d be 38 sets?item 4.14.13, Network Video Recorder 64 Ch. by 6,240 sets, but in drawing it’d be only 1 set?item 4.14.18, LED TV 43 Inch by 3,120 sets, but in drawing it’d be 2 sets?2 sets of water tanks are in the drawings, but in the BOQ are not exist?ANSWER:* BOQ of the Structure Works (Bill 2)Yes* BOQ of the Architecture Works (Bill 3)Detailed description in each of the Items 3.12.27; 3.12.28 & 3.12.29 (Build-In)Ceramic tile as per the boq detailed* BOQ of the Electrical Systems (Bill 4)7 sets as per the updated BOQ46 sets as per the updated boqset as per the updated boq4 sets as per the updated boqThe two water tanks included in reinforced concrete wall RW1 and RW2 in the boq 2.2.3.7 & 2.2.3.8
Edited on:
11-Dec-2024 06:26
Edited by:
webservice@unops.org
New amendment added #4: The amendment is made to upload the revised BOQ (Annex 1). The updates include:BOQ item 2.2.3.7 & 2.2.3.8BOQ description item 2.2.2.1BOQ items 4.14.1 to 4.14.25
Edited on:
10-Dec-2024 01:33
Edited by:
webservice@unops.org
New clarification added: QUESTION:We have downloaded the files you uploaded on eSourcing on December 5th, including the Pre-Bid Meeting minutes. In this document, in paragraph 3. Q&A Session, answer 8. you inform the bidders that the "BoQ will be revised and uploaded in eSourcing". We check the eSourcing platform regularly and notice that the revised BoQ has not been uploaded yet. Could you please inform us when you expect to share the new BoQ? Thank you.Considering that this document is crucial for bidders to prepare their offer and that there are only 7 days left before the deadline, are you considering extending the deadline again? Also considering that the end of year holidays are approaching, we would appreciate it if the submission date could be postponed to the first week of January.ANSWER: The revised BOQ has been uploaded on eSourcing. Due to the project's tight timeline, unfortunately, we are not able to extend the bid submission deadline any further.
Edited on:
09-Dec-2024 17:14
Edited by:
webservice@unops.org
New clarification added: QESTION:Cloud you please provide the calculation document in Appendix (Annex O ARUP-UNOPS-00070_Detailed Final Report for Mechanical, Electrical, Plumbing & Drainage and Fire Protection) because in the Appendix is empty.ANSWER:The updated version has been uploaded in the e-sourcing.
Edited on:
09-Dec-2024 10:18
Edited by:
webservice@unops.org
New clarification added: QUESTION: What is the requirement to prevent the soil collapse, due to in the BoQ mention about the Secant pile 820 m2 but in the specification mention to sheet pile, the price is different.ANSWER: Pleae follow the description in the BoQ. The specifications will be updated accordignly.QUESTION: Can the bidder offer alternative with the Jack in pile instead of Secant pile or sheet pile, due to the Secant pile will take a lot of muddy soil coming out, make the site dirty and also has to waiting for 28days at least in order for Secant pile more high strength and for the sheet pile work if cannot hammer down as the project required because of soil condition underground, it will take times to install and removal.ANSWER: Bidders should follow the given specifications & drawings for pricing.QUESTION: There are no quantities for water stop in the underground water tank, please confirm?ANSWER: Please refer to the updated BOQ description No. 2.2.3.7 & 2.2.3.8. This item has now been included.QUESTION: There are no quantities for water proofing in the underground water tank but available in the specification (Annex R ARUP-UNOPS-00029…item 9.2 product), please confirm?ANSWER: Specification prevails. Please include all necessary costs to the relavent BoQ items.QUESTION: Could you please confirm that the quantity for underground is already in the foundation works?ANSWER: The basement and ground slabs are mass foundations which will be support by underground structure.QUESTION: There are no quantities for anti-termite but mention in the specification, please confirm?ANSWER: Please refer to the updated BOQ description No. 2.2.2.1. This item has now been included. & refer drawings & specifications for details.QUESTION: According to the ceiling system/SCG material catalog (Pro-line system) the maximum thickness of galvanized is 0.52mm but the specification is mention 0.8mm (Annex R ARUP-UNOPS-00029_Page 39) and there is also no thickness size for ceiling main channel galvanized sheet steel 38x12x1.2mm, please confirm?ANSWER: Can use 0.52mm. The specification has been updated.QUESTION: Could you please check the BoQ for Bill 4-EE IT _Electronic Security System (item 4.14.1 to 4.14.17) there are different from the drawing?ANSWER: The quatity for each of these items have been updated in the revised BoQ.QUESTION: Could you please confirm that in the BoQ is required for the Smoke dector only three sets?ANSWER: The smoke dectors, shown in the fire portection for the gas suppresion system, are only 5 units. However, the quantity of the smoke detectors should also count from the electrical drawings. The smoke detectors have 138, please check BOQ Bill 4 EE IT 4.13.8
Edited on:
09-Dec-2024 10:14
Edited by:
webservice@unops.org
New amendment added #3: This amendment is made to upload the below files:Annex O ARUP-UNOPS-00070_Detailed Final Report for Mechanical, Electrical, Plumbing & Drainage and Fire Protection (Rev.1)Annex R ARUP-UNOPS-00029_The Particular Specification for Architecture_Rev A_Issued_Rev.1_09122024 (Rev.1)
Edited on:
09-Dec-2024 10:13
Edited by:
webservice@unops.org
New clarification added: QUESTION:Could you please confirm that the epoxy coating is not necessary to make self-leveling for water barrier?ANSWER:ConfirmedQUESTION:For the firefighting system works: In the BoQ is available for Carbon dioxide Portable Fire Extinguisher (CO2)/ 10 cylinder, but there is not available in the drawing where to install? please confirm?ANSWER:The CO2 Fire extingusher shall be install at every EE rooms including Generator, MDB and server rooms.QUESTION:For the firefighting system works: There are no quantities for CO2 and N2 control panel?ANSWER:No CO2 gas suppresion system to be applied in the building. Only the N2 gas suppression system which the control panel is installed in the front of the rooms.QUESTION:For the firefighting system works: the controlling of the CO2 and N2 want to separate control panel or not? Please confirm?ANSWER:No CO2 gas suppresion system to be applied in the building. Only the N2 gas suppression system which the control panel shall separate for the individual rooms.QUESTION:For the firefighting system works: There are no quantities pipe line to supply for N2?ANSWER:It's already included in section 5.8 fire hydrant pipe dia 40mm.QUESTION:For the firefighting system works: In the drawing, there are no details for CO2 diagram, please confirm?ANSWER:There is no CO2 gas suppresion system apply in the building.QUESTION:For the firefighting system works: In the drawing and BoQ, there are two locations (server room and switch board room) that required for N2 and how about the control panel, does the bidder has to quote the price for two control panel or one control panel, please confirm?ANSWER:The control panel is installed in the front of each rooms as shown in the drawing no. FS-DG-2013. The control panel shown include as assessory for N2 gas provision. Which we need 1 control panel as indicated in the drawing.QUESTION:For the firefighting system works: How many solenoids valve is required to be installed for CO2 and N2, please confirm?ANSWER:1 to Main switch board room and 1 to server room. We need 2 solenoids valves.
Edited on:
07-Dec-2024 09:25
Edited by:
webservice@unops.org
New clarification added: Question: The Tender document requires the bidder to attached the material specification list in to submission or not? Please confirm?Answer: The specifications of the items proposed by bidders in their bids must meet or exceed the minimum requirements outlined in the bidding documents. The bidders are not required to submit material specifications along with their bid. However, all materials provided by the selected bidder will be subject to the engineer's approval during implementation.
Edited on:
05-Dec-2024 05:43
Edited by:
webservice@unops.org
New clarification added: Question: We would like to request CAD file for Construction Works for the Proposed Headquarters Building & Training Center for the Department of Customs.Answer: We will share the CAD file with the awarded bidder only.
Edited on:
05-Dec-2024 05:41
Edited by:
webservice@unops.org
New amendment added #2: The tender amendment is made to:Upload pre-bid meeting slides and minutes as well as site visit minutes;Upload Annex G - The Particular Specification for General Engineering (Rev.1);Upload Section II, III, IV, V (Rev.1) - please note that the qualification criteria under Section II: Evaluation Method and Criteria has been slightly revised (see highlighted on page 3). The other sections remain the same.Extend the deadline for clarifications to 10 Dec 2024, 5.00 PM (GMT+7)Extend the bid submission deadline to 16 Dec 2024, 2.00 PM (GMT+7)
Edited on:
05-Dec-2024 04:33
Edited by:
webservice@unops.org
New amendment added #1: The tender amendment is made to upload the Particular Specification for Architecture
Edited on:
28-Nov-2024 05:55
Edited by:
webservice@unops.org
New clarification added: Question:hi, whether the signatory in the signature column under the form filled in by the bidder is the signature of the bidder's representative, and if it is, should we provide the letter of authorisation from the company?Answer:The bidding forms should be signed by the bidder's authorised representative. Please note that a Letter of Authorisation is not required.
Edited on:
24-Nov-2024 05:34
Edited by:
webservice@unops.org