CANCELLED Supply and Delivery of Laptop computers and UPS for Ethiopian Public Health Institute, Addis Ababa, Ethiopia
UNOPS
CANCELLED Supply and Delivery of Laptop computers and UPS for Ethiopian Public Health Institute, Addis Ababa, Ethiopia
Invitation to bid
Reference:
ITB/2022/43083
Beneficiary countries or territories:
Ethiopia
Registration level:
Basic
Published on:
16-Aug-2022
Deadline on:
04-Sep-2022 09:00 0.00
Description
The United Nations Office for Project Services , Ethiopian Multi-country office (hereinafter referred to as UNOPS ETMCO) is pleased to invite competent Bidders to submit their respective competitive Bids for the Supply and Delivery of Laptop computers and UPS for Ethiopian Public Health Institute, Addis Ababa, Addis Ababa, Ethiopia in accordance with the UNOPS General Conditions of Contract and “Schedule of Requirements” herein uploaded under file ITB_Section_II_Schedule of Requirements.
- Supply and Delivery of Laptop computers and UPS
This tender has been posted through the UNOPS eSourcing system. / Cet avis a été publié au moyen du système eSourcing de l'UNOPS. / Esta licitación ha sido publicada usando el sistema eSourcing de UNOPS. Vendor Guide / Guide pour Fournisseurs / Guíra para Proveedores: https://esourcing.unops.org/#/Help/Guides
First name:
N/A
Surname:
N/A
This procurement opportunity integrates considerations for at least one sustainability indicator. However, it does not meet the requirements to be considered sustainable.
Sustainable resource use
Environmental
The tender contains sustainability considerations promoting the sustainable use of resources.
Examples:
Energy-saving measures, recycling, take-back programmes and responsible end-of-life management
Link | Description | |
---|---|---|
https://esourcing.unops.org/#/Help/Guides | UNOPS eSourcing – Vendor guide and other system resources / Guide pour fournisseurs et autres ressources sur le système / Guía para proveedores y otros recursos sobre el sistema |
39121011
-
Uninterruptible power supply UPS
43211508
-
Personal computers
Tender cancelled on 2022-11-08 17:45 UTC. Lot No 1 & 2 - Both Lots will be canceled due to an Unsucssfull outcome. New tender will be posted in the near future. For any inquiries, please contact Betelhem Kumera KITILA. Email: BetelhemK@unops.org, Phone: Ethiopia 251911512310
Edited on:
08-Nov-2022 18:45
Edited by:
webservice@unops.org
New clarification added: Dear Bidders,Please note that this tender will be closed on Sunday 04-09-2022 at 09:00 UTC. Thus, be aware of the date and prepare your submission accordingly.Regards,
Edited on:
01-Sep-2022 16:33
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarification provided against requests received from interested bidder:Bidder`s request:1. Would be kind to share with all potential suppliers the space allocated for The UPS and battery rack space of this location? Do we have enough space to accommodate the UPS and the battery rack unit installation in one space? Do we run long distance cables between the UPS and the battery unit and the Power connecting point? 2. Can you precise the application : 1.a.: 2x40kVA to be redundant on a single 40kVA load (1+1 redundancy)OR 1.b.: 1x40kVA (with N+1 redundancy capability) for 1 40 kVA load + 1x40kVA (with N+1 redundancy capability) for 1 40 kVA load (2 loads of 40kVA in total). In case you are intending to use 2x40kVA UPS together to protect 1 40kVA load, would you accept 1 modular UPS rackable cabinet with 3x25kW redundant power modules? (N+1 redundancy).UNOPS response:1.Our partner has enough space in their data center that can handle the UPS and the battery rack. The distance between the power connection point to the UPS is approximately 20 meters.2. The UPS is needed for two separate Data Centers. Thus, 1x40kVA (with N+1 redundancy capability) for 1 40 kVA load + 1x40kVA (with N+1 redundancy capability) for 1 40 kVA load (2 loads of 40kVA in total) but it can be modular. With regards,
Edited on:
01-Sep-2022 10:16
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarification provided against request received from interested bidder:Bidder`s request:We kindly request the due date to be extended by 1 week, to 11 September, so we can get the details for the local services portion of the UPS in place.UNOPS response:Kindly note that the goods are urgently needed by the partner. Thus, we can not extend the deadline any longer.With regards,
Edited on:
30-Aug-2022 16:00
Edited by:
webservice@unops.org
New amendment added #1: Dear Bidders, The following sections have been amended in the ITB.Section II: Schedule of Requirement replaced as Section II: Schedule of Requirement rev1.Section III: Returnable Documents replaced as Section III: Returnable Documents revi 1.Deadline for Submission has been extended to 04 September 2022 at 09:00 Hrs (UTC)Deadline for Clarifications has been extended to 31 August 2022 at 09:00 Hrs (UTCRegards,
Edited on:
29-Aug-2022 17:16
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarification provided against request received from interested bidder:Bidder`s request:For Lot 1, High Performance Laptop Computer - please advise how much storage you want? HDD or SSD and capacity.UNOPS response:Storage: 1TB SSD or betterMemory Capacity: 32GB DDR4 or betterWith regards,
Edited on:
26-Aug-2022 17:03
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarification provided against a request received from an interested bidder:Bidder`s request:For LOT 1 could you accept an 16'' FHD Display?UNOPS response:As per the minimum technical specification stated under Section II - Schedule of requirement, the required display type is UHD.With regards,
Edited on:
23-Aug-2022 16:41
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarifications provided against request received from interested bidder:Bidder`s request:1.We are interested in bidding in this tender but we can see you ask for the bidder to have a local representative/Agent in Ethiopia. We do not have a representation but the producers we represent do, so the offered products can be repaired under warranty if needed. Is this OK?2. We are interested in this bid. However, we would like to participate as a joint venture with our partner in Europe that is qualified and can supply all the goods directly to you. Question;i.- Can our partner be the main supplier [we being the local representative ] and give you a quote?ii.- If awarded, would payment be transferred directly to our partner?UNOPS response:1. The bidder should have a local representative/Agent in Ethiopia to perform Installation, commissioning, Inspection and after sale service.2. Interested bidders can participate in a Joint Venture. Please note that if bidders participate as a joint venture, each joint venture member must meet the preliminary criteria and qualification criteria stated under this ITB.i. Either of the JV partners can be the leading partner on this ITB, Please include this information on Form A: Joint Venture Partner Information Formii. They payment will be effected to the main contractor (on the name of the partner for whom the PO is issued)With regards,
Edited on:
23-Aug-2022 08:26
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarifications provided against request received from interested bidder:Bidder`s request:1. Would be able to clarify the following elements for the UPS? Is it possible to a battery system to achieve either 28 mins at 40kVA or 40 mins at 40kVA?Could you please confirm which you would prefer? Obviously 40mins at 40kVA will be more expensive.2. Would be able to elaborate the following parameters?UPS RedundancyN+1 or N+x or betterUPS ArchitecturePARALLELMount typeRack mountedBatteryBuilt in or External cabinet with required communication and manageable accessories3. Do you want 2x 400V Modular 45kVA UPS (with 5x 15kW Power Modules) N+1 in parallel?4. I am working with APC on the UPS for this request and they are not sure what to offer based on the long list of details your provided as none match the request. They ask if it is possible for you to provide the make and model for the 40KVA you had in mind when presenting the required specifications.UNOPS response:The required battery system is a minimum of 30 minutes.We need modular UPS (expansion rack capacity to 60KVA) with configurable characteristics. So the architecture of the UPS should be parallel for redundancy configuration ( as we requested two UPSs(40KVA), they need to have such capability for redundancy). Any three phase Modular UPS that meet the minimum specification stated under Section II - Schedule of requirement and with AC output voltage 220V for the end terminals is acceptablePlease note that the technical specifications are brand neutral. Thus, kindly offer a product that will meet the minimum requirements.With regards,
Edited on:
22-Aug-2022 11:40
Edited by:
webservice@unops.org
New clarification added: Dear Bidders, Please see below clarifications provided against request received from interested bidder:Bidder`s request:During our search for the UPS that accomplishes all the requirements, we need clarification on the rack capacity.We do not really know if this issue is referred to the UPS capacity itself, or the capacity of the UPS batteries, and its relationship with the 40 KVA requirement.UNOPS response:A modular UPS system is built from a combination of individual UPS modules that are linked and work together.Modular UPS systems are housed in racks, The rack capacity is the maximum capacity that the rack can house (60KVA). The Required UPS capacity is 40 KVA.With regards,
Edited on:
17-Aug-2022 10:11
Edited by:
webservice@unops.org